Chapter 7 - Controlling the Printer SYSVAR Values and Descriptions (continued) Value 22 23 24 26 27 28 29 30 31 32 33 34 35 36 37 39 41 42 43 44 45 46 47 48 49 50 51 53 54 Description Returns the number of dots in the printhead. Returns 1 if a transfer ribbon is detected, 0 otherwise. Returns 1 if a power-up has been performed since last SYSVAR(24), or 0 otherwise. Returns 1 if the ribbon sensor detects that the diameter of the ribbon supply roll is equal to or less than the diameter specified in Setup Mode, or 0 otherwise. Sets condition for label reprinting at out-of-ribbon error. Decides if the information on the position of the media against the printhead should be cleared or not when the printhead is lifted. Returns Data Send Ready (DSR) condition on "uart2:". Returns Data Send Ready (DSR) condition on "uart3:". Returns last control character sent from the MUSE protocol (special applications). Returns the length of media (in 10-meter increments) that have been fed past the printhead. Returns Data Send Ready (DSR) condition on "uart1:". Sets or returns TrueType® character positioning mode. Sets or returns permanent or volatile setup saving. Sets or returns whether changes of program mode should be printed to the Debug Std Out port in connection with debugging. Sets or returns minimum gap length. Enables or disables slack compensation. Sets or returns conditions for overriding error detection at predefined feed length. Sets or returns conditions for aligning the gaps in the media with the tear bar. Sets or returns file name conversion enabled or disabled. Sets or returns current state of filtering of NUL characters during background communication. Returns the printhead resolution in dots per inch. Returns 1 if the paper low sensor detects that the diameter of the media supply roll is equal to or less than the diameter specified in Setup Mode, or 0 otherwise. Sets or returns current state of using Start Adjust and Stop Adjust values together with FORMFEED values. Sets or returns use of bidirectional Direct Protocol. Temporarily sets a lower print speed after a negative Start Adjust value. Sets a lower print speed after lowering the printhead. Sets the enabled limit for SYSVAR 49 and 50. Sets or returns the highest allowed diamter (in mm) of the ribbon supply. Modifies the DNS timeout value. Default is 5 (150 seconds). Each increment or decrement equals ±30 sec. Fingerprint Developer's Guide 117

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163

Chapter 7 — Controlling the Printer
Fingerprint Developer’s Guide
117
22
Returns the number of dots in the printhead.
23
Returns 1 if a transfer ribbon is detected, 0 otherwise.
24
Returns 1 if a power-up has been performed since last SYSVAR(24), or 0
otherwise.
26
Returns 1 if the ribbon sensor detects that the diameter of the ribbon supply roll
is equal to or less than the diameter specified in Setup Mode, or 0 otherwise.
27
Sets condition for label reprinting at out-of-ribbon error.
28
Decides if the information on the position of the media against the printhead
should be cleared or not when the printhead is lifted.
29
Returns Data Send Ready (DSR) condition on “uart2:”.
30
Returns Data Send Ready (DSR) condition on “uart3:”.
31
Returns last control character sent from the MUSE protocol (special
applications).
32
Returns the length of media (in 10-meter increments) that have been fed past the
printhead.
33
Returns Data Send Ready (DSR) condition on “uart1:”.
34
Sets or returns TrueType
®
character positioning mode.
35
Sets or returns permanent or volatile setup saving.
36
Sets or returns whether changes of program mode should be printed to the
Debug Std Out port in connection with debugging.
37
Sets or returns minimum gap length.
39
Enables or disables slack compensation.
41
Sets or returns conditions for overriding error detection at predefined feed
length.
42
Sets or returns conditions for aligning the gaps in the media with the tear bar.
43
Sets or returns file name conversion enabled or disabled.
44
Sets or returns current state of filtering of NUL characters during background
communication.
45
Returns the printhead resolution in dots per inch.
46
Returns 1 if the paper low sensor detects that the diameter of the media supply
roll is equal to or less than the diameter specified in Setup Mode, or 0 otherwise.
47
Sets or returns current state of using Start Adjust and Stop Adjust values
together with FORMFEED values.
48
Sets or returns use of bidirectional Direct Protocol.
49
Temporarily sets a lower print speed after a negative Start Adjust value.
50
Sets a lower print speed after lowering the printhead.
51
Sets the enabled limit for SYSVAR 49 and 50.
53
Sets or returns the highest allowed diamter (in mm) of the ribbon supply.
54
Modifies the DNS timeout value. Default is 5 (150 seconds). Each increment or
decrement equals ±30 sec.
SYSVAR Values and Descriptions
(continued)
Value