Invacare 3GRX-CG Owners Manual - Page 109
Adjusting the Extended Active Anti-Tippers
View all Invacare 3GRX-CG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
8.16 Adjusting the Extended Active Anti-Tippers 8 SETUP/MAINTENANCE ƽ WARNING Pinch points exist between seat and base frames. Use caution, otherwise injury may occur. Anti-Tippers must be used at all times. When outdoors on wet, soft ground or on gravel surfaces, anti-tippers may not provide the same level of protection against tip over. Extra caution must be observed when traversing such surfaces. Wheelchairs equipped with ventilator tray MUST have extended active anti-tippers installed, otherwise, injury or damage may occur. Wheelchairs that are NOT equipped with optional ventilator tray MUST have either the standard anti-tippers or the optional extended active anti-tippers installed, otherwise, injury or damage may occur. Refer to Detail "A" and Detail "B" in FIGURE 15. For this procedure, refer to FIGURE 15 on page 110. The extended active anti-tippers are standard when the wheelchair is equipped with a ventilator tray. The recommended height requirement for the anti-tippers, which is factory preset, is ¼-inch off the ground/floor. 1. Loosen locknuts A, B and C. 2. Lift anti-tipper and place ¼-inch block underneath the wheel. 3. Tighten locknut A upward against the bearing. 4. Tighten locknut B upward against locknut A. 5. Tighten locknut C downward against bearing inside anti-tip assembly. 6. Remove ¼-inch block. 7. Repeat STEPS 1-6 for the remaining anti-tip assembly. 8. Install the dust cover onto each anti-tip assembly. Part No 1143151 109 Invacare 3G Storm Series®