Invacare 3GRX-CG Owners Manual - Page 116
CMPJ+, PSR+, PSF+ Joysticks or Displays
View all Invacare 3GRX-CG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
9 TROUBLESHOOTING NUMBER OF FLASHES 7 8 9 10 11 ERROR CODE DESCRIPTION Remote Fault Controller Fault Communications Fault General Fault Incompatible or incorrect Remote POSSIBLE SOLUTION Check to make sure joystick is connected properly. Turn Joystick off then on. Contact Invacare/Dealer for service. Contact Invacare/Dealer for service. Check joystick cable connections. Check joystick cable and connectors for damage. Contact Invacare/Dealer for service. Contact Invacare/Dealer for service. Wrong type of remote connected. Contact Invacare/Dealer for service. CMPJ+, PSR+, PSF+ Joysticks or Displays SYMPTOM PROBABLE CAUSE SOLUTIONS LEFT BRAKE FAULT or RIGHT BRAKE FAULT displays and wheelchair does not drive. Motor lock levers disengaged (Error Engage motor lock levers. Refer to Disengaging/Engaging code E9 or E10). Motor Lock Levers on page 61. CHARGER PLUGGED IN displays. Battery charger connected (Error Unplug battery charger from the wheelchair. Refer to code E28). Charging Batteries on page 56. BATTERY FAULT displays and the wheelchair Batteries need to be charged (Error Charge batteries. Refer to Charging Batteries on page 56. If does not drive. code E14). batteries fail to charge properly, check battery charger or replace batteries. Refer to Replacing Batteries on page 86. JOYSTICK TIMEOUT displays and the wheelchair does not drive. Joystick or input device is disconnected (Error code 32). Turn off power, reconnect the joystick of input device and turn power on. Invacare 3G Storm Series® 116 Part No 1143151