JVC RMP-2580U RM-P2580 Dome Controller Instructions (1148KB) - Page 20
JVC RMP-2580U - Remote Controller For Color Domes Manual
View all JVC RMP-2580U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
4. CONNECTIONS A MODE The master monitor displays the video signal from the selected camera. Use the CAMERA SW input to switch the video signal and record it on the VCR. The preset operation, manual operation, AUTO PAN operation and AUTO PATROL operation are available for each camera. When fixed cameras are used, only the video signal can be switched. The alarm operation is available using the DATA I/O terminals. Alarms with up to 64 positions per camera can be handled via the SERIAL-1 connector. In the A mode, in which the camera signals are input directly to the VIDEO INPUT connectors on the rear panel, the DATA I/O terminals outputs as shown in the following table : Terminal Name AUTO Condition - Signals The MAKE signal is output for between 500 ms and 1000 ms duration in the following cases. ● Power OFF ¨ ON. ● AUTO SEQUENCE (AUTO button OFF → ON) ● When an AUTO SEQUENCE operation which has been interrupted by an alarm input resumes. The MAKE signal is output for between 500 ms and 1000 ms duration from the terminal corresponding to the camera number in the following cases. ● When AUTO SEQUENCE is turned OFF, the MAKE signal is output to the Camera No. terminal corresponding to the camera displayed on the camera indication. ● With AUTO SEQUENCE set to OFF, each time when the camera is selected, the MAKE signal is output to the Camera No. terminal corresponding to the camera selected. ● If an Alarm is input when AUTO SEQUENCE is activated, the MAKE signal is output to the Camera No. terminal corresponding to the camera to which the Alarm signal is input. ● If the PRIORITY item is set to ALARM, when there is an Alarm input while AUTO SEQUENCE is OFF, the MAKE signal is output to the Camera No. terminal corresponding to the camera to which the Alarm signal is input. I/O 1 to 8 (I/O 9/ to 16/8) When 8 SEL OUT is set • I/O 1 to 8 correspond to cameras 1 to 8. When 8 ALM OUT is set • I/O 1 to 8 corresponds to cameras 1 to 8. The MAKE signal is output for between 500 ms and 1000 ms duration in the following cases. ● The main signal is output at the terminal corresponding to the number of the camera which sent the alarm signal. UNIT ALARM - The MAKE signal is output continuously throughout the alarm period. CAMERA SW - The MONITOR OUTPUT 2 signal will be as follows, depending on the setting of the "CAM SWITCH". OFF : Same video signal as MONITOR OUTPUT 1, regardless of the CAMERA SW terminal. LOW : The camera's video signal is switched at the next VD after the falling signal from the time-lapse VCR is received. HIGH : The camera video is switched at the next VD after the raising signal from the time-lapse VCR is received. 20