JVC SR-9090U SR-9090U Timelapse Recorder Instruction Manual (1137KB) - Page 10

JVC SR-9090U - High Resolution 960 Hour Density Manual

Page 10 highlights

2 CONTROLS AND CONNECTORS 2-1 Front Panel 24 25 26 SR-9090U REC REC STOP REC CHECK OPERATE HDR EJECT OPERATE RESET/ CANCEL ON SCREEN SHIFT REW REVERSE PAUSE PLAY FF TRACKING V. LOCK TIMER SEARCH DISPLAY LOCK CNT RESET MENU TIME MODE - SET FIELD REV FIELD ADV - + - + + 16 17 18 19 ^ [SEARCH] button Use to search the alarm recorded section or a section recorded at a specified date and time. In the Stop mode, select the search mode by pressing this button. • Press once to engage the Alarm Search mode. • Press twice to engage the Alarm Scan mode. • Press three times to engage the Date/Time Search mode. • Press four times to release the search mode. After the search mode is selected with this button, press the [FF] or [REW] button to execute the search operation in the selected mode. For details, refer to page 49. 20 21 22 23 w [TIME MODE/SET +/-] buttons • Use to select the recording and playback speed mode. Available recording/playback speed modes vary depending on the setting of menu switch on the screen. Each time these buttons are pressed, the recording/ playback speed mode changes as follows. The recording/ playback speed mode is shown on the display. HDR recording: OFF 2H: Standard 6H: 3x 24H: 24-hour SP timelapse 48H: 48-hour SP timelapse 72H: 72-hour SP timelapse 120H: 120-hour SP timelapse 168H: 168-hour SP timelapse 240H: 240-hour SP timelapse 480H: 480-hour SP timelapse 960H: 960-hour SP timelapse HDR recording: ON 2H: Standard 6H: 3x 24H: 24-hour EP timelapse 48H: 48-hour EP timelapse 72H: 72-hour EP timelapse 120H: 120-hour EP timelapse 168H: 168-hour EP timelapse 240H: 240-hour EP timelapse 480H: 480-hour EP timelapse 960H: 960-hour EP timelapse & [DISPLAY] button Selects which data - current time, control tape counter (00H 00M 00S - 23H 59M 59S) or reel tape counter (0 - 9999) - is displayed. Each time this button is pressed, the display switches to the next item. * [LOCK] button Press to activate the operation lock function. • ( [CNT RESET] button When the display shows the control tape counter or reel tape counter, press this button to reset to "00H00M00S" or "0000". Also use these buttons during date/time setting, timer program setting and menu switch setting to specify setting values. • Use these buttons on the normal screen to move the display position or recording position of on-screen information. The position can be moved down by pressing the 7 button and to the right by pressing the t button. • Use these buttons on the menu screen to select the desired item in date/time setting, timer program setting and menu switch setting. e [ON SCREEN/SHIFT 7/t] buttons ) [RESET/CANCEL] button • In the Timer Program Setting mode, press this button to cancel the program settings. For details, refer to "Timer Recording" on page 36. • Also press this button to interrupt alarm recording or to reset the alarm input data or power loss (power failure) data. For details, refer to pages 21 and 39. • Resets the seconds in the currently displayed time to 00 when pressed together with the ( [CNT RESET] button (except in menu setting mode). - When the seconds value is 29 or less, the minutes value is the same but the seconds value is reset to 0. (eg. 12:34:29 [ 12:34:00) - When the seconds value is 30 or more, the seconds value is reset to "00" and the minutes value is increased by one. (e.g. 12:34:30 [12:35:00) r Display section For details, refer to page 11. t [OPERATE] indicator Lights when the [OPERATE] button is turned on. y [HDR] indicator Lights in the HDR recording and HDR playback modes. * HDR: High Density Recording • For details on HDR recording, refer to page 28. q [MENU] button Press to display the date/time, timer program, and various other menu setting screens, as well as the hour meter, on the monitor. Press again to cancel the menu or hour meter display. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65

10
2-1
Front Panel
w
[TIME MODE/SET +/–] buttons
• Use to select the recording and playback speed mode.
Available recording/playback speed modes vary
depending on the setting of menu switch <HDR> on the
<VTR MODE> screen.
Each time these buttons are pressed, the recording/
playback speed mode changes as follows.
The recording/
playback speed mode is shown on the display.
HDR recording: OFF
HDR recording: ON
2H: Standard
2H: Standard
6H: 3x
6H: 3x
24H: 24-hour SP timelapse
24H: 24-hour EP timelapse
48H: 48-hour SP timelapse
48H: 48-hour EP timelapse
72H: 72-hour SP timelapse
72H: 72-hour EP timelapse
120H: 120-hour SP timelapse
120H: 120-hour EP timelapse
168H: 168-hour SP timelapse
168H: 168-hour EP timelapse
240H: 240-hour SP timelapse
240H: 240-hour EP timelapse
480H: 480-hour SP timelapse
480H: 480-hour EP timelapse
960H: 960-hour SP timelapse
960H: 960-hour EP timelapse
Also use these buttons during date/time setting, timer
program setting and menu switch setting to specify setting
values.
e
[ON SCREEN/SHIFT
7
/
t
] buttons
• Use these buttons on the normal screen to move the
display position or recording position of on-screen
information.
The position can be moved down by pressing
the
7
button and to the right by pressing the
t
button.
Use these buttons on the menu screen to select the desired
item in date/time setting, timer program setting and menu
switch setting.
r
Display section
For details, refer to page 11.
t
[OPERATE] indicator
Lights when the [OPERATE] button is turned on.
y
[HDR] indicator
Lights in the HDR recording and HDR playback modes.
* HDR: High Density Recording
• For details on HDR recording, refer to page 28.
^
[SEARCH] button
Use to search the alarm recorded section or a section
recorded at a specified date and time.
In the Stop mode,
select the search mode by pressing this button.
• Press once to engage the Alarm Search mode.
• Press twice to engage the Alarm Scan mode.
Press three times to engage the Date/Time Search mode.
• Press four times to release the search mode.
After the search mode is selected with this button, press
the [FF] or [REW] button to execute the search operation
in the selected mode.
For details, refer to page 49.
&
[DISPLAY] button
Selects which data — current time, control tape counter
(00
H
00
M
00
S
— 23
H
59
M
59
S
) or reel tape counter (0 —
9999) — is displayed.
Each time this button is pressed, the
display switches to the next item.
*
[LOCK] button
Press to activate the operation lock function.
(
[CNT RESET] button
When the display shows the control tape counter or reel tape
counter, press this button to reset to “00
H
00
M
00
S
” or “0000”.
)
[RESET/CANCEL] button
• In the Timer Program Setting mode, press this button to
cancel the program settings.
For details, refer to “Timer
Recording” on page 36.
• Also press this button to interrupt alarm recording or to
reset the alarm input data or power loss (power failure)
data.
For details, refer to pages 21 and 39.
• Resets the seconds in the currently displayed time to 00
when pressed together with the
(
[CNT RESET] button
(except in menu setting mode).
- When the seconds value is 29 or less, the minutes value
is the same but the seconds value is reset to 0. (eg.
12:34:29
[
12:34:00)
- When the seconds value is 30 or more, the seconds value
is reset to “00” and the minutes value is increased by one.
(e.g. 12:34:30
[
12:35:00)
q
[MENU] button
Press to display the date/time, timer program, and various other
menu setting screens, as well as the hour meter, on the
monitor.
Press again to cancel the menu or hour meter display.
2
CONTROLS AND CONNECTORS
24
25
26
22
23
20
19
18
17
16
SR-9090U
REC
REC
STOP
REC
CHECK
EJECT
OPERATE
REVERSE
FIELD REV
FIELD ADV
REW
PLAY
TRACKING
TIMER SEARCH
RESET/
CANCEL
DISPLAY
LOCK
HDR
CNT RESET
MENU
TIME
MODE
SHIFT
ON SCREEN
OPERATE
V. LOCK
PAUSE
FF
+
+
SET
+
21