JVC VN-C3WU Instruction manual on the VN-C3WU Vnetworks camera (938,203 bytes, - Page 13
Connecting to a network - factory default
View all JVC VN-C3WU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
2. Connecting to a network Turn on the power of only one VN-C3WU unit. When network connection is completed and the power is turned on, the VN-C3WU unit will be connected to the network at the following IP address. Factory set (Default) IP address 192. 168. 0. 2 h Use a straight cable when connecting to a hub. Use a cross cable when connecting directly to a PC. Power supply connection cable q About the power supply connection cable • Length: 30m or less. • Recommended model: UL1007, UL1015 or equivalent cable with wire equivalent to ID AWG #20 or larger. Caution All VN-C3WU units are set to the same IP address at the factory; therefore, if the power of multiple VN-C3WU units is turned on at the same time, address duplication will occur and correct access will not be possible. Always turn the power on for only one unit at a time. If address duplication occurred, perform the proper processing and wait for 10 min. or more, or turn off the power of all units on the network and then turn the power on again; otherwise, correct access may not be possible. Caution VN-C3WU unit is intended to be Supplied by a Listed Direct Plug-In Power Unit marked "Class 2" and rated from 11 to 15 V dc, 2 to 2.5 A. 13