Jenn-Air JGD8130ADS Installation Instruction - Page 1

Jenn-Air JGD8130ADS Manual

Page 1 highlights

INSTALLATION MANUAL CONVERTIBLE GAS GRILL COOKTOP SERIES JGD8130 & JGD8345 403 WEST FOURTH STREET, NORTH · NEWTON, IA 50208 DIMENSIONS SHOWN IN BOTH INCHES AND CENTIMETERS *Blower may be rotated for horizontal or vertical direction by loosening nuts around blower inlet. Accessible inside ventilation chamber. S NOTICE TO INSTALLER: Leave these instructions with the appliance. S NOTICE TO CONSUMER: Retain these instructions for future reference. TIE DOWN BOLT ON EACH END BLOWER CAN BE SWIVELED 90_ 15/16² Min. Clearance 2.38 cm APPLIANCE PRESSURE REGULATOR GREASE CONTAINER 29² + 1/16² 73.66 cm WIRING BOX COVER 21² + 1/16² 53.34 cm 7 9/16² 19.21 cm 9 3/8² 23.81 cm 13² 33.02 cm 1 7/8² Min. 4.76 cm TIE DOWN BOLT ON EACH END BLOWER CAN BE SWIVELED 90_ GREASE CONTAINER 43 1/4² + 1/16² 109.86 cm APPLIANCE PRESSURE REGULATOR WIRING BOX COVER 21² + 1/16² 53.34 cm 7 9/16² 19.21 cm 15/16² Min. Clearance 2.38 cm 9 3/8² 23.81 cm 13² 33.02 cm 1 7/8² Min. 4.76 cm SELECT APPROPRIATE DUCT CUT OUT (SEE DUCTING INSTALLATION INSTRUCTIONS). SELECT APPROPRIATE DUCT CUT OUT (SEE DUCTING INSTALLATION INSTRUCTIONS). INSTRUCTIONS TO INSTALLER S Dimension "A" - Provide 2² min. (5.08 cm) cabinet clearance to motor for cooling purpose. S Note - Where possible, 6² (15.24 cm) is recommended for motor/blower service. S Side Clearance - Grills installed near a side wall must allow a minimum clearance of 8². S Access must be provided to remove and empty grease container(s). 8101P580-60 (04-04-00)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

8101P580-60
(04-04-00)
INSTALLATION
MANUAL
CONVERTIBLE GAS GRILL
COOKTOP SERIES
JGD8130 & JGD8345
403 WEST FOURTH STREET, NORTH
±
NEWTON, IA 50208
29
²
+
1/16
²
73.66 cm
DIMENSIONS SHOWN IN BOTH INCHES AND CENTIMETERS
*Blower may be rotated for horizontal or vertical direction by loosening nuts around blower inlet. Accessible inside ventilation
chamber.
S
NOTICE TO INSTALLER:
Leave these instructions with the appliance.
S
NOTICE TO CONSUMER:
Retain these instructions for future reference.
INSTRUCTIONS TO INST
ALLER
S
Dimension “A” - Provide 2
±
min. (5.08 cm) cabinet clearance to motor for cooling purpose.
S
Note
- Where possible, 6
±
(15.24 cm) is recommended for motor/blower service.
S
Side Clearance - Grills installed near a side wall must allow a minimum clearance of 8
±
.
S
Access must be provided to remove and empty grease container(s).
TIE DOWN BOLT
ON EACH END
BLOWER CAN BE
SWIVELED 90
_
GREASE
CONTAINER
WIRING BOX COVER
APPLIANCE PRESSURE
REGULATOR
21
²
+
1/16
²
53.34 cm
7
9/16
²
19.21 cm
1
7/8
²
Min.
4.76 cm
13
²
33.02 cm
9
3/8
²
23.81 cm
15/16
²
Min.
Clearance
2.38 cm
SELECT APPROPRIATE
DUCT CUT OUT (SEE
DUCTING INSTALLA-
TION INSTRUCTIONS).
43 1/4
²
+
1/16
²
109.86 cm
21
²
+
1/16
²
53.34 cm
7
9/16
²
19.21 cm
1
7/8
²
Min.
4.76 cm
13
²
33.02 cm
9
3/8
²
23.81 cm
15/16
²
Min.
Clearance
2.38 cm
SELECT APPROPRIATE
DUCT CUT OUT (SEE
DUCTING INSTALLA-
TION INSTRUCTIONS).
TIE DOWN BOLT
ON EACH END
BLOWER CAN BE
SWIVELED 90
_
GREASE
CONTAINER
WIRING BOX COVER
APPLIANCE PRESSURE
REGULATOR