Jenn-Air JGD8130ADS Installation Instruction - Page 6

To Convert Appliance For Use With Propane, Warning - model

Page 6 highlights

TO CONVERT APPLIANCE FOR USE WITH PROPANE GAS Natural Gas To Propane Gas (LP) Conversion Instructions WARNING Propane Gas conversion is to be performed by a Jenn-Air Authorized Service Contractor (or other qualified agency) in accordance with the manufacturer's instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for this conversion. WARNING ELECTRICAL POWER AND GAS MUST BE TURNED OFF PRIOR TO CONVERSION LR CR RR RF Models - JGD8130 & JGD8345 Series Manifold - Propane Gas pressure required - 10² W.C. Incoming Propane Gas pressure required to appliance pressure regulator - 11² - 12² W.C. Propane Gas conversion orifice hoods are supplied with these models. Propane Gas input specified - JGD8130/JGD8345 33,000 BTU/hr / 51,000 BTU/hr. TIE DOWN BOLT ON EACH END GREASE CONTAINER LF CF APPLIANCE PRESSURE REGULATOR WIRING BOX COVER BLOWER CAN BE SWIVELED 90_ JGD8345 (Shown) BURNER Left Rear (LR) Left Front (LF) Right Rear (RR) Right Front (RF) Center Rear (CR) Center Front (CF) BTU/hr 7,500 7,500 9,000 9,000 9,000 9,000 ORIFICE #66 #66 #63 #63 #63 #63 INCHES DIAMETER .0330 .0330 .0370 .0370 .0370 .0370 COLOR Zinc Zinc Blue Blue Blue Blue 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

6
TO CONVERT APPLIANCE FOR USE WITH PROPANE
GAS
Propane Gas conversion is to be performed by a
Jenn-Air Authorized Service Contractor (or other
qualified
agency)
in
accordance
with
the
manufacturer’s instructions and all codes and
requirements of the authority having jurisdiction.
Failure to follow instructions could result in serious
injury or property damage. The qualified agency
performing this work assumes responsibility for this
conversion.
WARNING
ELECTRICAL POWER AND GAS MUST BE
TURNED OFF PRIOR TO CONVERSION
TIE DOWN
BOLT ON
EACH END
BLOWER CAN BE
SWIVELED 90
_
GREASE
CONTAINER
WIRING BOX COVER
APPLIANCE PRESSURE
REGULATOR
LR
LF
RF
RR
Natural Gas To Propane Gas (LP) Conversion Instructions
Models - JGD8130 & JGD8345 Series
Manifold - Propane Gas pressure required - 10
±
W.C.
Incoming Propane Gas pressure required to appliance
pressure regulator - 11
±
- 12
±
W.C.
Propane Gas conversion orifice hoods are supplied with
these models.
Propane Gas input specified - JGD8130/JGD8345 -
33,000 BTU/hr / 51,000 BTU/hr.
JGD8345 (Shown)
INCHES
BURNER
BTU/hr
ORIFICE
DIAMETER
COLOR
Left Rear (LR)
7,500
#66
.0330
Zinc
Left Front (LF)
7,500
#66
.0330
Zinc
Right Rear (RR)
9,000
#63
.0370
Blue
Right Front (RF)
9,000
#63
.0370
Blue
Center Rear (CR)
9,000
#63
.0370
Blue
Center Front (CF)
9,000
#63
.0370
Blue
CR
CF
WARNING