Y.I I WARNING Electrical Shock Hazard Do not operate the cleaner without the motor safety filter. Be sure the filter is dry and properly installed to prevent motor failure and/or electrical shock. 2. Pull out the dust bin and motor safety filter as shown. Check motor safety filter occasionally and clean when dirty. 1. Unplug cord from wall outlet and lift canister hood. 3. Wash filter in warm soapy water, rinse, then dry. Do not clean in dishwasher or install while damp, 4. Insert motor safety filter back into canister. 5. Place the dust bin and close the hood. 1. Unplug cord from wall outlet. DO NOT drip water on cleaner. 2. Clean vacuum exterior using a clean, soft cloth that has been dipped in clean water, then wrung out. Wipe dry after cleaning. NOTE: Regular cleaning helps to reduce static electricity and dust buildup on outer surfaces of cleaner and attachments. CAUTION DO NOT use attachments if they are wet. Damage to motor may occur. Attachments used in dirty areas, such as under a refrigerator, should not be used on other surfaces until they are washed since they could leave marks. When not in use, store the cleaner in upright position by inserting nozzle clip into storage clip in canister body as shown. Nozzle Clip / -10-