Kenmore 33176 Owners Manual - Page 10
Insulation, Blankets
View all Kenmore 33176 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
This water heater must not be installed directly on carpeting. Carpeting must be protected by metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches (76.2 mm) in any direction, or if the appliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may result in a fire hazard. __12" MAX. (30 cm) VENTiLATiON AiR OPENING O AIR DUCT Fire or Explosion Hazard using or servicing water heater. • Improper use may result in fire or explosion. , Maintain required clearances to combustibles. Minimum clearances between the water heater and combustible construction are 0 inch at the sides and rear, 4 inches (102 mm) at the front, and 6 inches (153 mm) from the vent pipe, see Figure 8. Clearance from the top of the jacket is 12 inches (305 mm) on most models. Note that a lesser dimension may be allowed on some models, refer to the label attached adjacent to the gas control valve on the water heater. TOP VIEW OF CLOSET WITHOUT DOOR 0" MIN. TOP VIEW OF CLOSET WITH DOOR 0" MIN. _{ 104M0"IN. 0" MIN. " NIIN, 4 ram) FRONT VIEW OF DOOR FIGURE 9. If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken from outside these areas. Propellants of aerosol sprays and volatile compounds, (cleaners, chlorine based chemicals, refrigerants, etc.) in addition to being highly flammable in many cases, will also change to corrosive hydrochloric acid when exposed to the combustion products of the water heater. The results can be hazardous, and also cause product failure. Insulation Blankets Insulation blankets available to the general public for external use on gas water heaters are not necessary with Kenmore products. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. Your Kenmore water heater meets or exceeds the EPACT standards with respect to insulation and standby loss requirements, an insulation blanket unnecessary. making FIGURE 8. Breathing Hazard - Carbon Monoxide Gas Breathing Hazard - Carbon Monoxide Gas 1,:_. .:'_'.°:., _;.:, : :_,::_. :?:"i_i if':° " Install water heater in accordance with the instruction manual and NFPA54. ° To avoid injury, combustion and o Do not obstruct water heater air intake with insulating blanket. Gas and carbon monoxide detectors are available. o Install water heater in accordance with the instruction manual. Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual. _: _!._! _ outdoors.Ventailiar ti°nmust be taken from . Dproodnuoctsplnaecaer cwhaetemrichael atvear.por emitting Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual. A gas water heater cannot operate properly without the correct amount of air for combustion, see Figure 9. Do not install in a confined area such as a closet, unless you provide air as shown in the Combustion Air and Ventilation forAppliances Located in Confined Spaces section. Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas supplier. Failure to provide the proper amount of combustion air can result in a fire or explosion and cause death, serious bodily injury, or property damage. ,_ WARNING Should you choose to apply an insulation blanket to this heater, you should follow these instructions (See Figure 1 for identification of components mentioned below). Failure to follow these instructions can restrict the air flow required for proper combustion, potentially resulting in fire, asphyxiation, serious personal injury or death. Do not apply insulation to the top of the water heater, as this will interfere with safe operation of the draft hood. Do not cover the outer door, thermostat or temperature & pressure relief valve. Do not allow insulation to come within 2" (50.8 mm) of the floor to prevent blockage of combustion air flow to the burner. 10