U.L.-Listed Conduit

Page 5 highlights

If cooktop is used in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle, or where local codes DO NOT permit grounding through the neutral (white) wire: If your cooktop has a 3-wire cable (see figure 6): 1. Disconnect the power supply. 2. Separate the green (or bare copper) and white appliance cable wires. 3. Cap the white wire from the power supply cable if a 3-wire appliance cable is supplied. 4. In the circuit breaker, fuse box or junction box: connect appliance and power supply cable wires as shown in figure 6. If your cooktop has a 4 wire cable (see figure 7): 1. Disconnect the power supply. 2. Separate the green (or bare copper) and white appliance cable wires. 3. In the circuit breaker, fuse box or junction box: connect appliance and power supply cable wires as shown in figure 7. Cable from Power Supply Ground Wire _-'-m Red /-White ires] Cable from Power Supply Ground Wire Red Wires .White Wire Wires Box Ground Wire >......i....... (Bare or Green Wire a _ U.L.-Listed Conduit Connector (or CSA listed) Cable from appliance Figure 6 4-WIRE GROUNDED JUNCTION BOX (Bare or Green _

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

If cooktop
is used in a new
branch
circuit
installation
(1996
NEC), mobile
home,
recreational
vehicle,
or where
local
codes
DO NOT permit
grounding
through
the
neutral
(white)
wire:
If your
cooktop
has a 3-wire
cable
(see figure
6):
1. Disconnect the power
supply.
2. Separate the green (or bare copper) and white
appliance
cable wires.
3. Cap the white
wire from the power
supply cable if a
3-wire
appliance cable is supplied.
4. In the circuit
breaker, fuse box or junction
box:
connect
appliance and power
supply cable wires as
shown
in figure
6.
Cable from
Power Supply
Ground Wire
Red
Wires
.White Wire
Wires
Box
Ground Wire
>
.............
i
(Bare or Green
Wire)
"
...........
a
_
U.L.-Listed Conduit
Connector (or CSA
listed)
Cable from appliance
Figure
6
4-WIRE
GROUNDED
JUNCTION
BOX
If your
cooktop
has a 4 wire
cable (see figure
7):
1. Disconnect the power
supply.
2. Separate the green (or bare copper) and white
appliance cable wires.
3. In the circuit
breaker, fuse box or junction
box:
connect appliance and power
supply cable wires as
shown in figure 7.
Cable from Power Supply
Ground Wire
_-'-m
/-White
Red
ires]
(Bare or Green
_<<_Y_
] _q_ _
I
Wire)
/
nduit
Junction Box
Connector (or CSA listed)
Cable from appliance
Figure
7
4-WIRE GROUNDED
JUNCTION
BOX
If
connecting
to
a 4-wire
power
supply
cable
electrical
system,
the appliance
frame
connected
ground
wire
MUST
NOT be connected
to
the
neutral
wire
of the 4-wire
electrical
system.