Kenwood KAC-X520 Instruction Manual - Page 4

Controls / Indicator - amp

Page 4 highlights

Controls / Indicator INFRASONIC OFF ON B.M.S. OFF REMOTE +12dB FILTER OFF HPF LPF OPERATION STEREO MONO(L ch) GND LINE IN LINE OUT EXT.AMP.CONT. L L R R INFRASONIC OFF ON B.M.S. OFF REMOTE +12dB FILTER OFF HPF LPF 1 2 3 OPERATION STEREO MONO(L ch) 4 5 6 7 8 9 5 INPUT SENSITIVITY control Adjust this control according to the pre-out level of the center unit connected to this amplifier. NOTE Refer to "Specifications" on the center unit's instruction manual about the pre-out level. 4 OPERATION switch This switch is used to select the operation mode of the amplifier. • STEREO position: The amplifier can be used as a stereo amplifier. • MONO (Lch) position: Amplifies the signal input from the left side only. Set to this position and make bridged connections to use as a high-power monaural amplifier. (The input right signal is not output.) 3 FILTER switch This switch allows to apply high-pass or low-pass filtering to the speaker outputs. • HPF (High-Pass Filter) position: The filter outputs the band of higher frequencies than the frequency set with the HPF FREQUENCY control. • OFF position: The entire bandwidth is output without filtering. • LPF (Low-Pass Filter) position: The filter outputs the band of lower frequencies than the frequency set with the LPF FREQUENCY control. The speaker output is automatically turned monaural (L+R) and the bass boost function is activated. 9 HPF FREQUENCY control Sets the cutoff frequency when the FILTER switch is set to HPF. 8 LPF FREQUENCY control Sets the cutoff frequency when the FILTER switch is set to LPF. 1 INFRASONIC FILTER switch When this switch is ON, the frequencies which are below the audible range and therefore inaudible are cut off so that the quality of the audible frequencies can be improved. 2 B.M.S.(Bass management system) switch Bass boost centered on the frequency set by the B.M.S. FREQUENCY control. • +12 position: Bass boost +12 dB • OFF position: Bass boost OFF • REMOTE position: Controls the B.M.S. from the Kenwood center unit. (Refer to page 5) 6 B.M.S. FREQUENCY control When the B.M.S. switch is set on "+12dB"/ "REMOTE" the emphasized center frequency is adjusted. 7 V-COLOR (Variable color) button Select the ON color for the indicator. Every time the button is pressed, 7 fixed colors and the variable color change. The color can't be set when the indicator is blinking. 4 English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

4
English
Controls / Indicator
ON
OFF
INFRASONIC
FILTER
OFF
HPF
B.M.S.
+12dB
OFF
REMOTE
OPERATION
GND
LINE OUT
EXT.AMP.CONT.
LINE IN
L
R
L
R
ON
OFF
INFRASONIC
FILTER
LPF
OFF
HPF
B.M.S.
+12dB
OFF
REMOTE
OPERATION
MONO(L ch)
STEREO
1
2
3
4
5
6
8
9
7
5
INPUT SENSITIVITY control
Adjust this control according to the pre-out
level of the center unit connected to this
amplifier.
Refer to "Specifications" on the center
unit’s instruction manual about the pre-out
level.
4
OPERATION switch
This switch is used to select the operation
mode of the amplifier.
• STEREO position:
The amplifier can be used as a stereo
amplifier.
• MONO (Lch) position:
Amplifies the signal input from the left side
only. Set to this position and make bridged
connections to use as a high-power
monaural amplifier. (The input right signal is
not output.)
3
FILTER switch
This switch allows to apply high-pass or
low-pass filtering to the speaker outputs.
• HPF (High-Pass Filter) position:
The filter outputs the band of higher
frequencies than the frequency set with the
HPF FREQUENCY control.
• OFF position:
The entire bandwidth is output without
filtering.
• LPF (Low-Pass Filter) position:
The filter outputs the band of lower
frequencies than the frequency set with the
LPF FREQUENCY control.
The speaker output is automatically turned
monaural (L+R) and the bass boost function
is activated.
9
HPF FREQUENCY control
Sets the cutoff frequency when the FILTER
switch is set to HPF.
8
LPF FREQUENCY control
Sets the cutoff frequency when the FILTER
switch is set to LPF.
1
INFRASONIC FILTER switch
When this switch is ON, the frequencies
which are below the audible range and
therefore inaudible are cut off so that the
quality of the audible frequencies can be
improved.
2
B.M.S.(Bass management system)
switch
Bass boost centered on the frequency set
by the B.M.S. FREQUENCY control.
• +12 position:
Bass boost +12 dB
• OFF position:
Bass boost OFF
• REMOTE position:
Controls the B.M.S. from the Kenwood
center unit. (Refer to page 5)
6
B.M.S. FREQUENCY control
When the B.M.S. switch is set on "+12dB"/
"REMOTE" the emphasized center
frequency is adjusted.
7
V-COLOR (Variable color) button
Select the ON color for the indicator.
Every time the button is pressed, 7 fixed
colors and the variable color change.
The color can’t be set when the indicator is
blinking.
NOTE