Kenwood PKT-23 Operation Manual 1 - Page 23

QT/ DQT setting.

Page 23 highlights

5 Press the PTT switch to save the setting and switch to the QT/ DQT setting. • A beep will sound and the transceiver announces "QT". 6 Press the Up/Down key to select QT or DQT, then press the PTT switch to confirm the selection. 7 Press the Up/Down key to increment/ decrement the QT/ DQT number, to select the new value. • Press and hold the Up/Down key to continuously increment/ decrement the QT/ DQT number. • QT/ DQT numbers and their corresponding settings are provided in the tables on pages 15 to 17. • A voice announcement will inform you of the selected QT/ DQT number. 8 Press the PTT switch to save the setting. • A beep will sound and the transceiver announces "Channel Number". • Repeat steps 3 to 8 to set up another channel. 9 Press and hold the PF-2 key and PTT switch to store the settings and return to normal operation. Note: ◆ The transceiver will automatically return to normal operation if no action is performed for 20 seconds. ◆ Frequencies indicated by an asterisk * in the following table may be susceptible to interference from other frequencies. If interference occurs, change to a different frequency in the following table. Table Number 0 1 2 3 4* 5 6 7 8 Operating Frequency (MHz) OFF 464.5000 464.5500 467.7625 467.8125 467.8500 467.8750 467.9000 467.9250 Table Number 9 10* 11* 12* 13 14 15 16 17 Operating Frequency (MHz) 461.0375 461.0625 461.0875 461.1125 461.1375 461.1625 461.1875 461.2125 461.2375 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

13
5
Press the
PTT
switch to save the setting and switch to the
QT/ DQT setting.
A beep will sound and the transceiver announces “QT”.
6
Press the
Up/Down
key to select QT or DQT, then press the
PTT
switch to confirm the selection.
7
Press the
Up/Down
key to increment/ decrement the QT/
DQT number, to select the new value.
Press and hold the
Up/Down
key to continuously increment/
decrement the QT/ DQT number.
QT/ DQT numbers and their corresponding settings are
provided in the tables on pages 15 to 17.
A voice announcement will inform you of the selected QT/ DQT
number.
8
Press the
PTT
switch to save the setting.
A beep will sound and the transceiver announces “Channel
Number”.
Repeat steps 3 to 8 to set up another channel.
9
Press and hold the
PF-2
key and
PTT
switch to store the
settings and return to normal operation.
Note:
The transceiver will automatically return to normal operation if
no action is performed for 20 seconds.
Frequencies indicated by an asterisk * in the following table
may be susceptible to interference from other frequencies.
If interference occurs, change to a different frequency in the
following table.
Table Number
Operating
Frequency (MHz)
Table Number
Operating
Frequency (MHz)
0
OFF
9
461.0375
1
464.5000
10*
461.0625
2
464.5500
11*
461.0875
3
467.7625
12*
461.1125
4*
467.8125
13
461.1375
5
467.8500
14
461.1625
6
467.8750
15
461.1875
7
467.9000
16
461.2125
8
467.9250
17
461.2375