KitchenAid KDRP463LSS Installation Instructions - Page 6
KitchenAid KDRP463LSS - 36" Pro-Style Dual Fuel Range Manual
View all KitchenAid KDRP463LSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
WARNING WARNING Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to wall behind range. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. line Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge copper wire. Electrically ground range. Failure to follow these instructions can result in death, fire, or electrical shock. This range must be connected to a grounded, metallic permanent wiring system or a ground connector should be connected to the ground terminal or wire lead on the range. This range is manufactured with a frameconnected, green or bare ground wire factory-crimped to the neutral (white) wire. Connect the range cable to the junction box through the U.L.- or CSAlisted conduit connector. Complete electrical connection according to local codes and ordinances. 3. Connect the two black wires together; and the two red wires together using twist-on connectors. (See Figure 1.) 4. Separate the factory-crimped bare and white range cable wires. 5. Connect the two white wires together using twist-on connector. 6. Connect the bare ground wire from the range cable to the grounded wire in the junction box or other grounded connector using twist-on connector. (See Figure 1.) Do not connect bare ground wire to neutral (white) wire in junction box. 7B. Where local codes permit connecting the frame-ground conductor to the neutral (white) junction box wire (not used for Canadian installations): wall stud anti-tip bracket mounting screws junction box red wires white wire 3-wire cable from power supply black wires Position top of anti-tip bracket at line marked in step 5 and mark holes. Drill two 1/8" (3 mm) holes. Use screws provided to fasten anti-tip bracket to wall. NOTE: Anti-tip bracket must be mounted securely to stud in wall behind the range. Depending on thickness of the wall covering, longer screws may be required. 6. 7A. Where local codes Do Not permit connecting the frame-ground conductor to the neutral (white) junction box wire (also used for Canadian installations): 4-wire cable from power supply white and bare grounding oven cable wires - factory crimped 4-wire cable from range U.L.- or CSA- listed conduit connector Grounded neutral 7. Figure 2 junction box white wires Make electrical connection. red wires If your house has aluminum wiring, see "Electrical requirements" page 5. twist-on connector bare or green wires 4-wire cable from range black wires U.L.- or CSA- listed conduit connector Ungrounded neutral Figure 1 1. Disconnect power supply. 2. Connect the flexible, armored cable from the range to the junction box using a U.L.- or CSA-listed conduit connector. Tighten screws on conduit connector. 1. Disconnect power supply. 2. Connect the flexible, armored cable from the range to the junction box using a U.L.- or CSA-listed conduit connector. Tighten screws on conduit connector. 3. Connect the two black wires together; the two red wires together; and the factory-crimped bare and white cooktop cable wires to the white (neutral) wire in the junction box using twist-on connectors. (See Figure 2.) 6