KitchenAid KGSS907SBL Installation Instructions - Page 19

To Convert Standard Surface Burners, To Convert TripleTier, Flame Burner on some models

Page 19 highlights

Gas pressure regulator 4. Remove plastic cover from gas pressure regulator cap. 5. Turn gas pressure regulator cap (marked "LP" on front of gas pressure regulator) counterclockwise with a wrench to remove. NOTE: Do not remove the spring beneath the cap. F Side view before A BFD E N C Side view after A. Plastic cover B. Gas pressure regulator cap with hollow end facing out C. Gas pressure regulator cap with solid end facing out D. Washer E. Gas pressure regulator cap F. Gas regulator shutoff valve (shown in the "open" position) 6. Turn the gas pressure regulator cap over and reinstall on regulator so that the solid end faces out and letter "N" is visible. 7. Replace plastic cover over gas pressure regulator cap. To Convert Standard Surface Burners 1. Remove burner cap. 2. Using a T20® TORX® screwdriver, remove the burner base. 3. Apply masking tape to the end of a 7 mm nut driver to help hold the gas orifice spud in the nut driver while changing it. Press nut driver down onto the gas orifice spud and remove by turning it counterclockwise and lifting out. Set gas orifice spud aside. C A D B A. Igniter electrode B. Gas tube opening C. Burner cap D. Burner base 4. Gas orifice spuds are stamped with a number on the side. Replace the LP gas orifice spud with the correct Natural gas orifice spud. XXX A A. Stamped number Refer to the following chart for the correct Natural gas orifice spud placement. Natural Gas Orifice Spud Chart for Standard Surface Burners Burner Location Burner Rating Size Right front Left front Right rear Left rear 6,000 Btu/h 14,000 Btu/h 12,500 Btu/h 6,000 Btu/h 1.10 mm 1.70 mm 1.61 mm 1.10 mm 5. Place LP gas orifice spuds in plastic parts bag for future use and keep with package containing literature. 6. Replace burner cap. 7. Repeat steps 1-6 for the remaining burners, except for the TripleTier® Flame burner (on some models). See "To Convert TripleTier® Flame Burners" in the "Natural Gas Conversion" section. To Convert TripleTier® Flame Burner (on some models) 1. Remove burner cap. 2. Remove the burner head using a size T20® TORX® screwdriver. 3. Remove the plate on the external gas orifice spud. A B C D A. Burner caps B. Burner heads C. External gas orifice spud access plate D. Internal gas orifice spud 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

19
Gas pressure regulator
4.
Remove plastic cover from gas pressure regulator cap.
5.
Turn gas pressure regulator cap (marked “LP” on front of gas
pressure regulator) counterclockwise with a wrench to
remove.
NOTE:
Do not remove the spring beneath the cap.
6.
Turn the gas pressure regulator cap over and reinstall on
regulator so that the solid end faces out and letter “N” is
visible.
7.
Replace plastic cover over gas pressure regulator cap.
To Convert Standard Surface Burners
1.
Remove burner cap.
2.
Using a T20
®
TORX
®
screwdriver, remove the burner base.
3.
Apply masking tape to the end of a
7
mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Press nut driver down onto the gas orifice spud and remove
by turning it counterclockwise and lifting out. Set gas orifice
spud aside.
4.
Gas orifice spuds are stamped with a number on the side.
Replace the LP gas orifice spud with the correct Natural gas
orifice spud.
Refer to the following chart for the correct Natural gas orifice
spud placement.
Natural Gas Orifice Spud Chart for Standard Surface Burners
5.
Place LP gas orifice spuds in plastic parts bag for future use
and keep with package containing literature.
6.
Replace burner cap.
7.
Repeat steps 1-6 for the remaining burners, except for the
TripleTier
®
Flame burner (on some models). See “To Convert
TripleTier
®
Flame Burners” in the “Natural Gas Conversion”
section.
To Convert TripleTier
®
Flame Burner (on some models)
1.
Remove burner cap.
2.
Remove the burner head using a size T20
®
TORX
®
screwdriver.
3.
Remove the plate on the external gas orifice spud.
A. Plastic cover
B. Gas pressure regulator cap with hollow end facing out
C. Gas pressure regulator cap with solid end facing out
D. Washer
E. Gas pressure regulator cap
F. Gas regulator shutoff valve (shown in the “open” position)
A. Igniter electrode
B. Gas tube opening
C. Burner cap
D. Burner base
A
B
C
D
Side view before
Side view after
N
E
F
F
A
B
C
D
A. Stamped number
Burner Location
Burner Rating
Size
Right front
Left front
Right rear
Left rear
6,000 Btu/h
14,000 Btu/h
12,500 Btu/h
6,000 Btu/h
1.10 mm
1.70 mm
1.61 mm
1.10 mm
A. Burner caps
B. Burner heads
C. External gas orifice spud access plate
D. Internal gas orifice spud
XXX
A
A
B
C
D