Replacing the pre-separation pad, separation module.

Page 32 highlights

Replacing the preseparation pad 1. Remove the separation module from the scanner by following the steps previously described in "Replacing the separation module and tires". 2. Hold the separation module in both hands and locate the two side tabs which protrude slightly from the back of the separation module. 3. Push down on the side tabs until the pre-separation pad protrudes slightly from the front of the separation module. 4. Grasp the pre-separation pad and pull it out of the separation module. 4-10 5. Discard the worn pre-separation pad. 6. Align the side tabs of a new pre-separation pad with the slots on the separation module. 7. Push the pre-separation pad firmly in the slots until the pre- separation pad flap rests lightly against the separation module tires. 8. Reinstall the separation module by aligning the tabs with the slots and snapping it into position. A-61560 January 2010

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

4-10
A-61560
January 2010
Replacing the pre-
separation pad
1.
Remove the separation module from the scanner by following the
steps previously described in “Replacing the separation module and
tires”.
2.
Hold the separation module in both hands and locate the two side
tabs which protrude slightly from the back of the separation module.
3.
Push down on the side tabs until the pre-separation pad protrudes
slightly from the front of the separation module.
4.
Grasp the pre-separation pad and pull it out of the separation
module.
5.
Discard the worn pre-separation pad.
6.
Align the side tabs of a new pre-separation pad with the slots on the
separation module.
7.
Push the pre-separation pad firmly in the slots until the pre-
separation pad flap rests lightly against the separation module tires.
8.
Reinstall the separation module by aligning the tabs with the slots
and snapping it into position.