Konica Minolta AccurioPress 6136 AccurioPress 6136/6136P/6120 Daily Maintenanc - Page 105

Adjustment value of same screen, same paper type, same weight, and old date, low number.

Page 105 highlights

3.6 Details of quality adjustment items 3 11 Press [Start] on the screen. The second scan is carried out, and the density balance adjustment value is registered. 12 When the adjustment is completed normally, the adjustment value is automatically registered, and the screen shown below is displayed. Select whether to output the adjustment chart for confirmation purposes. % The adjustment value is registered according to the following conditions. When the there is an idle registration: The adjustment value is registered in the lowest idle number. When the there is no idle registration: The adjustment value is overwritten to the number that matches the following conditions. If multiple values match the conditions, they are overwritten preferentially from the condition of a low number. (1) Adjustment value of same screen, same paper type, same weight, and old date (2) Adjustment value of same screen, same paper type, and old date (3) Adjustment value of same screen and old date (4) Adjustment value of oldest date % If [Yes] is selected, you can output a check chart. After the chart is output, follow the procedure to scan the chart; the values before and after adjust- AccurioPress 6136/6136P/6120 3-36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

3.6
Details of quality adjustment items
3
AccurioPress 6136/6136P/6120
3-36
11
Press [Start] on the screen.
The second scan is carried out, and the density balance adjustment value is registered.
12
When the adjustment is completed normally, the adjustment value is automatically registered, and the
screen shown below is displayed. Select whether to output the adjustment chart for confirmation pur-
poses.
%
The adjustment value is registered according to the following conditions.
When the there is an idle registration:
The adjustment value is registered in the lowest idle number.
When the there is no idle registration:
The adjustment value is overwritten to the number that matches the following conditions.
If multiple values match the conditions, they are overwritten preferentially from the condition of a
low number.
(1) Adjustment value of same screen, same paper type, same weight, and old date
(2) Adjustment value of same screen, same paper type, and old date
(3) Adjustment value of same screen and old date
(4) Adjustment value of oldest date
%
If [Yes] is selected, you can output a check chart.
After the chart is output, follow the procedure to scan the chart; the values before and after adjust-