MRPA MRPA - Move to Relative Position specified by Angle Format MRPA distance, angle; Parameters distance: distance to move angle: angle in degree, measured clockwise from the vertical Function The MRPA command moves the cursor from its current position across a specified distance using a specified angle. The distance is measured in the units designated by the UNIT command. The MRPA command is ignored in the path mode graphics. To move to a relative position specifying angle in a path construction, use the PMRA (in Path, Move to Relative position by Angle) command. File !R! RES; UNIT C; CMNT Numbers indicate cursor movement; SFNT 'Helvetica-Bd'; MAP 6, 12; CIR 1; TEXT '1'; MRPA 2, 60; CIR 1; TEXT '2'; MRPA 2, 120; CIR 1; TEXT '3'; MRPA 2, 180; CIR 1; TEXT '4'; MRPA 2, 240; CIR 1; TEXT '5'; MRPA 2, 300; CIR 1; TEXT '6'; PAGE; EXIT; 169