Kyocera ECOSYS P6130cdn PRESCRIBE Commands Command Reference Manual Rev 5.1 - Page 198
Pczp
View all Kyocera ECOSYS P6130cdn manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 198 highlights
PRESCRIBE Command Reference PCZP - in Path, Curve to Zero-relative Position Format PCZP x1, y1, x2, y2, x3, y3; Parameters x1, y1: coordinates of the first control point as measured from the left and top edge limits of paper x2, y2: coordinates of second control point as measured from the left and top edge limits of paper x3, y3: coordinates of end point as measured from the left and top edge limits of paper Function The PCZP command adds a Bézier curve segment to the path, starting from the current cursor position through two controls points of (x1, y1) and (x2, y2), and ending at (x3, y3), measured from the left and top edge limits of the paper. Example: NEWP; PMZP 1.5, 3.5; PCZP 4.5, 1.5, 5.5, 5.5, 8, 3.5; STRK; (4.5, 1.5) Current position (1.5, 3.5) (8, 3.5) (5.5, 5.5) 188