Kyocera FS 3700 FS-1700/3700 Users Manual - Page 113

C>mode Com1:96, N

Page 113 highlights

C.4. RS-232C Cable Connection Baud rate=9600 bps, Data bits (character length)=8 bits, Stop bits=1, Parity=None The three RS-232C protocols are XON/XOFF and DTR. The printer performs all three of them simultaneously, using positive logic for DTR. If you are uncertain as to the printer's current parameter settings, you can reset them to the values listed above by following the manner described in the last page in this manual. 8. Set the computer to the same parameters as the printer. On many computers this can be done by setting DIP switches before power is turned on. Another method is as follows: In DOS, enter the following commands: C>MODE COM1:96,N,8,1,P C>MODE LPT1:=COM1 To test the interface, then enter: CTRL P C>DIR CTRL P The software settings made by the procedures above are temporary. On most computers, permanent settings must be made with DIP switches. If you want to use a different baud rate or change any of the other RS-232C parameters, you can use the printer's FRPO (firmware reprogram) command. See the Programming Manual for details. C-13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

Baud rate=9600 bps, Data bits (character length)=8 bits,
Stop bits=1, Parity=None
The three RS-232C protocols are XON/XOFF and DTR. The printer performs all three of
them simultaneously, using positive logic for DTR.
If you are uncertain as to the printer’s current parameter settings, you can reset them to
the values listed above by following the manner described in the last page in this man-
ual.
8.
Set the computer to the same parameters as the printer. On many computers this can be
done by setting DIP switches before power is turned on. Another method is as follows:
In DOS, enter the following commands:
C>MODE COM1:96,N,8,1,P
C>MODE LPT1:=COM1
To test the interface, then enter:
CTRL P
C>DIR
CTRL P
The software settings made by the procedures above are temporary. On most comput-
ers, permanent settings must be made with DIP switches.
If you want to use a different baud rate or change any of the other RS-232C parameters,
you can use the printer’s FRPO (firmware reprogram) command. See the
Programming
Manual
for details.
C.4.
RS-232C Cable Connection
C-13