Check Screen] Command: t z, Speaker] Command: d v, Daylight Saving Time] Command: s d

Page 83 highlights

Data 10 (Check Screen) Data1 00: C heck Screen result NG 07: C heck Screen result OK * Sets to NG when Check Screen is set to Off or not supported. Data Data1 Data2 13(For checking Door State) Number of the door to check 00: Closed 01: Opened Data 15 (when checking the current electric current value) Data1 Current electric current value in mA Data 16(For checking Humidity) Data1 Display the current humidity (%RH) in the Hex value Data 17(For checking Illuminance) Data1 Display the current illumination (Lux) in the Hex value Data Data1 18(For checking the Rotation (Gyro) State) 00: 0 degrees 01: 90 degrees 02: 180 degrees 03: 270 degrees Data 09 (In the case of Fan Speed) Acknowledgement (v)( )(Set ID)( )(OK/NG)(Data)(Data1)(Data2)(x) Data1 00-ff: The upper 1-byte of the fan speed Data2 00-ff: The lower 1-byte of the fan speed Fan speed: 0 to 2008 in hexadecimal and 0 to 8200 in decimal * This may not be supported on some models. 52. [Check Screen] (Command: t z) Sets Check Screen. Transmission (t)(z)( )(Set ID)( )(Data)(Cr) Data 00: Off 01: On Acknowledgement (z)( )(Set ID)( )(OK/NG)(Data)(x) * It may not be supported depending on the model. 55 53. [Speaker] (Command: d v) Sets the speaker function. Transmission (d)(v)( )(Set ID)( )(Data)(Cr) Data 00: Off 01: On Acknowledgement (v)( )(Set ID)( )(OK/NG)(Data)(x) * It may not be supported depending on the model. 54. [Daylight Saving Time] (Command: s d) To set the Daylight Saving Time function. Transmission (s)(d)( )(Set ID)( )(Data1)( )(Data2)( )(Data3)( )(Data4) ( )(Data5)(Cr) Data 00: Off (Data2~5: FFH) 01: Start Time 02: End Time Data2 01~0C: January to December Data3 01~06: 1~6th week * The maximum number of [Data3] differs depending on Date. Data4 00~06 ( Sun. ~ Sat. ) Data5 00~17: 00~23 hours * To read the Start Time/End Time, enter FFH for [Data2]~[Data5]. (Example 1: sd 01 01 ff ff ff ff - To check the Start Time) (Example 2: sd 01 02 ff ff ff ff - To check the End Time) * This function is supported only when 1 (Year/Month/ Day) and 2 (Hour/ Minute/Second) are set. Acknowledgement (d)( )(Set ID)( )(OK/NG)(Data1)(Data2)(Data3)(Data4) (Data5)(x) * It may not be supported depending on the model. ENGLISH_index

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

ENGLISH
55
Data
10 (Check Screen)
Data1
00: Check Screen result NG
07: Check Screen result OK
* Sets to NG when Check Screen is set to Off or not supported.
Data
13(For checking Door State)
Data1
Number of the door to check
Data2
00: Closed
01: Opened
Data
15 (when checking the current electric current value)
Data1
Current electric current value in mA
Data
16(For checking Humidity)
Data1
Display the current humidity (%RH) in the Hex value
Data
17(For checking Illuminance)
Data1
Display the current illumination (Lux) in the Hex value
Data
18(For checking the Rotation (Gyro) State)
Data1
00: 0 degrees
01: 90 degrees
02: 180 degrees
03: 270 degrees
Data
09 (In the case of Fan Speed)
Acknowledgement
(v)( )(Set ID)( )(OK/NG)(Data)(Data1)(Data2)(x)
Data1
00-ff: The upper 1-byte of the fan speed
Data2
00-ff: The lower 1-byte of the fan speed
Fan speed: 0 to 2008 in hexadecimal and 0 to 8200 in decimal
* This may not be supported on some models.
52.
[Check Screen] (Command: t z)
Sets Check Screen.
Transmission
(t)(z)( )(Set ID)( )(Data)(Cr)
Data
00: Off
01: On
Acknowledgement
(z)( )(Set ID)( )(OK/NG)(Data)(x)
* It may not be supported depending on the model.
53.
[Speaker] (Command: d v)
Sets the speaker function.
Transmission
(d)(v)( )(Set ID)( )(Data)(Cr)
Data
00: Off
01: On
Acknowledgement
(v)( )(Set ID)( )(OK/NG)(Data)(x)
* It may not be supported depending on the model.
54.
[Daylight Saving Time] (Command: s d)
To set the Daylight Saving Time function.
Transmission
(s)(d)( )(Set ID)( )(Data1)( )(Data2)( )(Data3)( )(Data4)
( )(Data5)(Cr)
Data
00: Off (Data2~5: FFH)
01: Start Time
02: End Time
Data2
01~0C: January to December
Data3
01~06: 1~6th week
* The maximum number of [Data3] differs depending on Date.
Data4
00~06 ( Sun. ~ Sat. )
Data5
00~17: 00~23 hours
* To read the Start Time/End Time, enter FFH for [Data2]~[Data5].
(Example 1: sd 01 01 ff ff ff ff - To check the Start Time)
(Example 2: sd 01 02 ff ff ff ff - To check the End Time)
* This function is supported only when 1 (Year/Month/ Day) and 2 (Hour/
Minute/Second) are set.
Acknowledgement
(d)( )(Set ID)( )(OK/NG)(Data1)(Data2)(Data3)(Data4)