Luminance Value Read] Command: m u, Fan Failure Check] Command: d w
![]() |
View all LG 55XS2E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
88. [Dual Screen Off] (Command: s n, 92) Turn Dual Screen On or Off. Transmission (s)(n)( )(Set ID)( )(9)(2)( )(Data)(Cr) Data 00: M ainScreen - On / SubScreen - On 01: M ainScreen - Off / SubScreen - On 02: M ainScreen - On / SubScreen - Off Acknowledgement (n)( )(Set ID)( )(OK/NG)(9)(2)(Data)(x) * This feature may not be supported in certain models. 89. [Fan control] (Command: d o) Sets the fan mode. Transmission (d)(o)( )(Set ID)( )(Data)(Cr) Data 00: Auto 01: On 02: Manual 03: Off Acknowledgement (o)( )(Set ID)( )(OK/NG)(Data)(x) * This may not be supported on some models. 90. [Fan Failure Check] (Command: d w) Checks for fan failures. Transmission (d)(w)( )(Set ID)( )(Data)(Cr) Data FF: Read status Acknowledgement (w)( )(Set ID)( )(OK/NG)(Data1)(Data2)(x) Data1 Data2 00: O ne or more fans are faulty. 01: A ll fans are normal. 02: The model has no fan. 00: N o fan is faulty (all fans are normal). 01: 1 fan is faulty. 02: 2 fans are faulty. 03: 3 fans are faulty. 04: 4 fans are faulty. 05: 5 fans are faulty. 06: 6 fans are faulty. 07: 7 fans are faulty. 08: 8 fans are faulty. 09: 9 fans are faulty. 0A: 1 0 fans are faulty. ... N: N down 63 91. [Luminance Value Read] (Command: m u) Reads luminance value. Transmission (m)(u)( )(Set ID)( )(FF)(Cr) Acknowledgement (u)()(SetID)()(OK/NG)(Data1)(Data2)(Data3) (Data4)(Data5)(Data6)(Data7)(x) Data1 00-64: The Backlight PWM value (0 to 100) Data2 00-ff: The upper 1-byte of the value measured by the CA210. Data3 00-ff: The lower 1-byte of the value measured by the CA210. CA210 measurement: 0 000 to ffff in hexadecimal and 0 to 65535 in decimal. Data4 00-ff: The upper 1-byte of the value measured by BLU 1 sensor. Data5 00-ff: The lower 1-byte of the value measured by BLU 1 sensor. Data6 00-ff: The upper 1-byte of the value measured by BLU 2 sensor. Data7 00-ff: The lower 1-byte of the value measured by BLU 2 sensor. BLU measurement: 0 000 to ffff in hexadecimal and 0 to 65535 in decimal. * During final assembly, a CA210 measurement is entered through the calibration procedure. The default value, before calibration, is 0. * This may not be supported on some models. 92. [BLU Maintenance] (Command: m t) Selects whether to turn on/off BLU Maintenance. Transmission (m)(t)( )(Set ID)( )(Data)(Cr) Data 00: BLU Maintenance Off 01: BLU Maintenance On Acknowledgement (t)( )(Set ID)( )(OK/NG)(Data)(x) * This may not be supported on some models. ENGLISH_index
![](/manual_guide/products/lg-55xs2e-owners-manual-78ba1bf/91.png)