Outdoor Unit, Select the Best Location

Page 14 highlights

Select the Best Location s Select installation location of the HR unit suitable for following conditions • Avoid a place where rain may enter since the HR unit is for indoor. • Sufficient service space must be obtained. • Refrigerant pipe must not exceed limited length. • Avoid a place subject to a strong radiation heat from other heat source. • Avoid a place where oil spattering, vapor spray or high frequency electric noise is expected. • Install the unit at a place in which it is not affected by operation noise. (Installation within cell such as meeting room etc. may disturb business due to noise.) • Place where refrigerant piping, drain piping and electrical wiring works are easy. 481(18-10/11) 7 100mm(3-15/16 in1c0h0) more (Serviceing space) 345(13-1/2) 450(17-3/4) 450(17-3/4) 300mm(11-7/8 inch) more 300mm(11-7/8 inch) more (NOTICE 2) 1 (Servicing space) (Servicing space) 2 3 100mmmo(r3e-15/16 inch) more (Serviceing space) Inspection door(NOTICE 1) (servicing space) 300mm(11-7/8 inch)more (NOTICE 2) (Servicing space) 450mm(17-3/4 inch) more (Servicing space) 124(4-7/8) 45 30(1-1/6) 60(2-3/8) 182(7-1/8) 128(5) 218(8-1/2) 174(6-7/8) 453(17-7/8) 174(6-7/8) No. Part Name 1 Low pressure Gas pipe connection port 2 High pressure Gas pipe connection port 3 Liquid pipe connection port 4 Indoor unit Gas pipe connection port 5 Indoor unit Liquid pipe connection port 6 Control box 7 Hanger metal 419(16-1/2) 6 61(2-7/16) 137(5-3/8) Description PRHR030A/040A (Unit: mm(inch)) PRHR020A Ø28.58(1-1/8) Brazing connection Ø22.2(7/8) Brazing connection Ø22.2(7/8) Brazing connection Ø19.05(3/4) Brazing connection Ø12.7(1/2) Brazing connection Ø9.52(3/8) Brazing connection Ø15.88(5/8) Brazing connection Ø15.88(5/8) Brazing connection Ø9.52(3/8) Brazing connection Ø9.52(3/8) Brazing connection - - M10 or M8 M10 or M8 NOTICE : 1. Be sure to install the inspection door at the control box side. 2. If reducers are used, servicing space must be increased equal to reducer's dimension. 14 Outdoor Unit

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93

14
Outdoor Unit
Select the Best Location
Select installation location of the HR unit suitable for following conditions
• Avoid a place where rain may enter since the HR unit is for indoor.
• Sufficient service space must be obtained.
• Refrigerant pipe must not exceed limited length.
• Avoid a place subject to a strong radiation heat from other heat source.
• Avoid a place where oil spattering, vapor spray or high frequency electric noise is expected.
• Install the unit at a place in which it is not affected by operation noise. (Installation within cell such as meeting
room etc. may disturb business due to noise.)
• Place where refrigerant piping, drain piping and electrical wiring works are easy.
Inspection door(NOTICE 1)
(servicing space)
481(18-10/11)
345(13-1/2)
300mm(11-7/8 inch) more
(Servicing space)
300mm(11-7/8 inch) more
(Servicing space)
300mm(11-7/8 inch)more
(Servicing space)
450mm(17-3/4 inch) more
(Servicing space)
1
2
3
5
4
6
7
453(17-7/8)
174(6-7/8)
174(6-7/8)
182(7-1/8)
218(8-1/2)
419(16-1/2)
61(2-7/16)
137(5-3/8)
124(4-7/8)
128(5)
30(1-1/6)
60(2-3/8)
(NOTICE 2)
(NOTICE 2)
450(17-3/4)
450(17-3/4)
100 more
100 more
(Serviceing space)
(Serviceing space)
100mm(3-15/16 inch) more
100mm(3-15/16 inch) more
(Serviceing space)
(Serviceing space)
100mm(3-15/16 inch) more
(Serviceing space)
100 more
100 more
(Serviceing space)
(Serviceing space)
100mm(3-15/16 inch) more
100mm(3-15/16 inch) more
(Serviceing space)
(Serviceing space)
100mm(3-15/16 inch) more
(Serviceing space)
:
1. Be sure to install the inspection door at the control box side.
2. If reducers are used, servicing space must be increased equal to reducer's dimension.
NOTICE
(Unit: mm(inch))
Description
PRHR030A/040A
PRHR020A
1
Low pressure Gas pipe connection port
Ø28.58(1-1/8) Brazing connection
Ø22.2(7/8) Brazing connection
2
High pressure Gas pipe connection port
Ø22.2(7/8) Brazing connection
Ø19.05(3/4) Brazing connection
3
Liquid pipe connection port
Ø12.7(1/2) Brazing connection
Ø9.52(3/8) Brazing connection
4
Indoor unit Gas pipe connection port
Ø15.88(5/8) Brazing connection
Ø15.88(5/8) Brazing connection
5
Indoor unit Liquid pipe connection port
Ø9.52(3/8) Brazing connection
Ø9.52(3/8) Brazing connection
6
Control box
-
-
7
Hanger metal
M10 or M8
M10 or M8
Part Name
No.