LG DLG5988WM Service Manual - Page 16
LG DLG5988WM Manual
View all LG DLG5988WM manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Component 13. Outlet Thermostat (Auto reset) • Check Top Marking : N95 13. Outlet Thermostat (Manual reset) • Check Top Marking : N100 Test Procedure Measure resistance of terminal to terminal Open at 203 ± 7°F (95 ± 5°C) Close at 158 ± 9°F (70 ± 5°C) Check result Resistance value ∞ Continuity < 1Ω Remark • Gas type • Gas funnel Measure resistance of terminal to terminal Open at 212 ± 12°F (100 ± 7°C) Manual reset If thermal fuse is open must be replaced Resistance value ∞ Continuity < 1Ω • Gas type • Gas funnel 16
16
Component
Test Procedure
Check result
Remark
13. Outlet Thermostat
(Auto reset)
•
Check Top Marking
:
N95
Measure resistance of terminal
to terminal
±
Open at 203 ± 7
°
F (95 ± 5
°
C)
²
Close at 158 ± 9
°
F (70 ± 5
°
C)
±
Resistance value
≒
∞
²
Continuity < 1
Ω
•
Gas type
•
Gas funnel
13. Outlet Thermostat
(Manual reset)
•
Check Top Marking
:
N100
Measure resistance of terminal
to terminal
±
Open at 212 ± 12
°
F
(100 ± 7
°
C)
²
Manual reset
If thermal fuse is open must
be replaced
±
Resistance value
≒
∞
²
Continuity < 1
Ω
•
Gas type
•
Gas funnel