LG LBC24360ST Service Manual - Page 45
Check B
View all LG LBC24360ST manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
11-2 CHECK B B1. LED blinks once, then repeats (FCT0 Fault) Protection Logic Blink OFF Blink OFF - Purpose: Detecting motor current and voltage error - Check voltage at point A (Motor Voltage), point B (Motor Current) andPoint C (Capacitor Voltage) when compressor is off. - Spec: Points A, B, & C 2.5V 0.3V GND Voltage Protection logic Check B Blink 1 time (FCT 0) Check B1 Out of spec? (2.2 - 2.8V) Y Replace Driver PCB N Reset Power B A C B2. LED blinks two times, then repeats (Stroke Trip) Protection Logic Blink Blink OFF Blink Blink OFF - Purpose: Prevent abnormally long piston strokes. - Case 1. If compressor doesn't work and LED blinks - Cause: Possibly harness from compressor to PCB might be defective. - Case 2. If compressor works intermittently and LED blinks - Cause: Condenser Fan or Freezer Fan is not running. Sealed system problem such as moisture restriction, restriction at capillary tube or refrigerant leak. - Logic: Compressor is forced to off and then tries to restart after 1 minute. Protection logic Check B Blink 2 times (Stroke Trip) Check B2 N Fix Harness Compressor Doesn't work Replace Driver PCB N Fix Cycle OK NG Cycle Check E Y Y Harness Y Connecting Check C Compressor Y Works Intermittently Repeat N Check Procedure Stroke Trip Occur? Reset Power Capacitor Spec. Check C Y Compressor Damage Check C Y N Replace Capacitor N Replace Compressor 45