ENGLISH How to Install the Unit 1 To prevent vibration and noise, make sure the unit is installed securely and firmly. 2 Install the unit where the sunlight does not shine directly on the unit. 3 The outside of the cabinet must extend outward and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner. 30"~60" Cooled air Awning Fence Heat radiation About 1/4" Over 20" CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure. 4 Install the unit a little slanted so the back is slightly lower than the front (about 1/4"). This will force condensed water to flow to the outside. 5 Install the unit with the bottom about 30"~60" above the floor level. Window Requirements NOTE: All supporting parts should be secured to firm wood, masonry, or metal. • This unit is designed for installation in standard double hung windows with actual opening widths from 26" to 39 3/8". • The top and bottom window sash must open sufficiently to allow a clear vertical opening of 12" from the bottom of the upper sash to the window stool. 26"(660mm) to 393/8"(1000mm) 12"(305mm) min. Inner sill Interior wall Sash Window Offset Sill Exterior 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

ENGLISH
About
1
/
4
"
30"~60"
Awning
Cooled air
Fence
Over 20"
Heat
radiation
26"(660mm) to
39
3
/
8
"(1000mm)
12"(305mm) min.
Inner sill
Offset
Window
Sill
Exterior
Interior wall
Sash
11
How to Install the Unit
To prevent vibration and noise, make sure the unit
is installed securely and firmly.
Install the unit where the sunlight does not shine
directly on the unit.
The outside of the cabinet must extend outward
and there should be no obstacles, such as a fence
or wall, within 20" from the back of the cabinet
because it will prevent heat radiation of the
condenser.
Restriction of outside air will greatly reduce the
cooling efficiency of the air conditioner.
CAUTION:
All side louvers of the cabinet must remain exposed to the outside of the structure.
Install the unit a little slanted so the back is slightly lower than the front (about 1/4").
This will force condensed water to flow to the outside.
Install the unit with the bottom about 30"~60" above the floor level.
5
4
3
2
1
Window Requirements
NOTE:
All supporting parts should be secured to firm wood, masonry, or metal.
• This unit is designed for installation in standard double
hung windows with actual opening widths from 26"
to 39
3
/
8
".
• The top and bottom window sash must open sufficiently
to allow a clear vertical opening of 12" from the bottom
of the upper sash to the window stool.