LG LP6000ER Owners Manual - Page 11
English - thru wall window air conditioner
View all LG LP6000ER manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
ENGLISH How to Install the Unit 1 To prevent vibration and noise, make sure the unit is installed securely and firmly. 2 Install the unit where the sunlight does not shine directly on the unit. 3 The outside of the cabinet must extend outward and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner. 30"~60" Cooled air Awning Fence Heat radiation About 1/4" Over 20" CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure. 4 Install the unit a little slanted so the back is slightly lower than the front (about 1/4"). This will force condensed water to flow to the outside. 5 Install the unit with the bottom about 30"~60" above the floor level. Window Requirements NOTE: All supporting parts should be secured to firm wood, masonry, or metal. • This unit is designed for installation in standard double hung windows with actual opening widths from 26" to 39 3/8". • The top and bottom window sash must open sufficiently to allow a clear vertical opening of 12" from the bottom of the upper sash to the window stool. 26"(660mm) to 393/8"(1000mm) 12"(305mm) min. Inner sill Interior wall Sash Window Offset Sill Exterior 11