LG LP6000ER Owners Manual - Page 12
Installation Kits Contents, Suggested Tool Requirements, Installation - weight
View all LG LP6000ER manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Installation Kits Contents A B C G F DE H ITEM A B C D E F G H NAME OF PARTS SUPPORT, BRACKET LEVELING BOLT LEVELING BOLT SCREW: 5/8" SCREW: 5/8" FOAM SEAL FOAM STRIP L BRACKET Q'TY 1 1 1 2 5 1 1 1 Suggested Tool Requirements SCREWDRIVER(Phillips and Flathead), RULER, KNIFE, HAMMER, PENCIL, LEVEL Installation CAUTION To avoid the possibility of personal injury, unplug power to unit before installing or servicing. Carefully remove air conditioner from carton, check for possible shipping damage. Pick a location which will allow you to blow the cold air into the area you want. Windows used for installation must be strong enough to support the weight of the air conditioner. Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed. When cooling more than one room, installation location is very important. To cool your rooms, cold air must be blown from the air conditioner in a straight path. If air conditioner is blocked by a storm window frame, see Step 7 and 8 on Page 14 before beginning to install. How to Install 1 Cut the FOAM STRIP (ITEM G) to fit the underside of the window sash. Open the window, peel off the backing and attach the FOAM STRIP as shown in FIG. 1. ; @; @ FOAM STRIP (ITEM G) FIG. 1 2 Mark center line with pencil on the center of the inner sill, as shown in FIG. 2. INDOOR CENTER LINE INNER SILL FIG. 2 12