LG LRFDS3006D Owners Manual - Page 24

Caution

Page 24 highlights

24 INSTALLATION 6 Route the tubing. • Route the tubing between the cold water line and the refrigerator. Route the tubing through a hole drilled in the wall or floor (behind the refrigerator or adjacent base cabinet) as close to the wall as possible. NOTE • Be sure there is sufficient extra tubing (about 8 ft. coiled into three turns of about 10 in. diameter) to allow the refrigerator to move out from the wall after installation. 7 Connect the tubing to the valve. • Place the compression nut and ferrule (sleeve) for copper tubing onto the end of the tubing and connect it to the shutoff valve. Make sure the tubing is fully inserted into the valve. Tighten the compression nut securely. 9 Connect the tubing to the refrigerator. NOTE • Before making the connection to the refrigerator, be sure that the refrigerator power cord is not plugged into the wall outlet. • Remove the plastic flexible cap from the water valve. • Place the compression nut and ferrule (sleeve) onto the end of the tubing as shown. • Insert the end of the copper tubing into the connection as far as possible. While holding the tubing, tighten the fitting. a Tubing Clamp b ¼ in. Tubing c ¼ in. Compression Nut d Ferrule (sleeve) e Refrigerator Connection a Saddle-Type Shutoff Valve b Compression Nut c Packing Nut d Outlet Valve e Ferrule (sleeve) 8 Flush out the tubing. • Turn the main water supply on and flush out the tubing until the water is clear. Shut the water off at the water valve after about one quart of water has been flushed through the tubing. 10 Turn the water on at the shutoff valve. • Tighten any connections that leak. CAUTION • Check to see if leaks occur at the water line connections.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

24
INSTALLATION
6
Route the tubing.
Route the tubing between the cold water line
and the refrigerator. Route the tubing
through a hole drilled in the wall or floor
(behind the refrigerator or adjacent base
cabinet) as close to the wall as possible.
NOTE
Be sure there is sufficient extra tubing
(about 8 ft. coiled into three turns of about 10 in.
diameter) to allow the refrigerator to move out
from the wall after installation.
7
Connect the tubing to the valve.
Place the compression nut and ferrule
(sleeve) for copper tubing onto the end of the
tubing and connect it to the shutoff valve.
Make sure the tubing is fully inserted into the
valve. Tighten the compression nut securely.
a
Saddle-Type Shutoff Valve
b
Compression Nut
c
Packing Nut
d
Outlet Valve
e
Ferrule (sleeve)
8
Flush out the tubing.
Turn the main water supply on and flush out
the tubing until the water is clear. Shut the
water off at the water valve after about one
quart of water has been flushed through the
tubing.
9
Connect the tubing to the refrigerator.
NOTE
Before making the connection to the
refrigerator, be sure that the refrigerator power
cord is not plugged into the wall outlet.
Remove the plastic flexible cap from the water
valve.
Place the compression nut and ferrule (sleeve)
onto the end of the tubing as shown.
Insert the end of the copper tubing into the
connection as far as possible. While holding the
tubing, tighten the fitting.
a
Tubing Clamp
b
¼ in. Tubing
c
¼ in. Compression Nut
d
Ferrule (sleeve)
e
Refrigerator Connection
10
Turn the water on at the shutoff valve.
Tighten any connections that leak.
CAUTION
Check to see if leaks occur at the water line