Lantronix IONPS6-D ION106 User Guide Rev E - Page 26

Sensors and Fan(s), Miscellaneous, Buttons

Page 26 highlights

Lantronix ION106-x User Guide Sensors and Fan(s) The IONPS6-x power supply fan speed automatically increases as the temperature sensed increases. Parameter Temperature Temperature Status Voltage Voltage Status Power Power Status Fan Speed Fan Status Associated MIB Variable entPhySensorValue(4) entPhySensorOperStatus(5) entPhySensorValue(4) entPhySensorOperStatus(5) entPhySensorValue(4) entPhySensorOperStatus(5) entPhySensorValue(4) entPhySensorOperStatus(5) Description The existing power supply temperature (e.g., 25 ̊C). The most recent measurement obtained by the agent for this sensor. The existing power supply temperature status (e.g., OK). The operational status of the sensor. The existing power supply voltage (e.g., 12000 miliVolts). The most recent measurement obtained by the agent for this sensor. The existing power supply voltage status (e.g., OK or Nonoperational). The operational status of the sensor. The existing power supply power reading (e.g., 49 Watts). The most recent measurement obtained by the agent for this sensor. The existing power supply power status (e.g., OK). The operational status of the sensor. The existing power supply fan speed in revolutions per minute (e.g., 5639 RPM). The most recent measurement obtained by the agent for this sensor (in RPM). The existing power supply fan status (e.g., OK). The operational status of the sensor. Miscellaneous Parameter Module Type Master/Slave Mode Associated MIB Variable xxxxxxxxxxx ionEntSensorExtOperMode(4) Description The currently installed IONPS module type, either: AC Module = IONPS6-A, or AC Module = IONPS6-D The current power supply mode (Master or Slave). Displays/sets the operational mode of the power supply when redundant PS modules exist (read / write). The Slave power supply is the fail-over or redundant (backup) power supply. Buttons Refresh: Click to update page data. Help: Click to display online help for the page. 33658 Rev. E https://www.lantronix.com/ 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Lantronix
ION106-x User Guide
33658 Rev. E
26
Sensors and Fan(s)
The IONPS6-x power supply fan speed automatically increases as the temperature sensed increases.
Parameter
Associated MIB
Variable
Description
Temperature
entPhySensorValue(4)
The existing power supply temperature (e.g.,
25
ĚŠ
C
).
The most recent measurement obtained by the
agent for this sensor.
Temperature Status
entPhySensorOperStatus(5)
The existing power supply temperature status
(e.g.,
OK
).
The operational status of the sensor.
Voltage
entPhySensorValue(4)
The existing power supply voltage (e.g.,
12000
miliVolts
).
The most recent measurement obtained by the
agent for this sensor.
Voltage Status
entPhySensorOperStatus(5)
The existing power supply voltage status (e.g.,
OK or Nonoperational
). The operational status of
the sensor.
Power
entPhySensorValue(4)
The existing power supply power reading (e.g.,
49
Watts
). The most recent measurement obtained
by the agent for this sensor.
Power Status
entPhySensorOperStatus(5)
The existing power supply power status (e.g.,
OK
).
The operational status of the sensor.
Fan Speed
entPhySensorValue(4)
The existing power supply fan speed in
revolutions per minute (e.g.,
5639 RPM
).
The
most recent measurement obtained by the agent
for this sensor (in RPM).
Fan Status
entPhySensorOperStatus(5)
The existing power supply fan status (e.g.,
OK
).
The operational status of the sensor.
Miscellaneous
Parameter
Associated MIB Variable
Description
Module Type
xxxxxxxxxxx
The currently installed IONPS module type,
either:
AC Module
= IONPS6-A, or
AC Module
= IONPS6-D
Master/Slave Mode
ionEntSensorExtOperMode(4)
The current power supply mode (
Master
or
Slave
).
Displays/sets the operational mode of the power
supply when redundant PS modules exist (read
/ write).
The Slave power supply is the fail-over
or redundant (backup) power supply.
Buttons
Refresh
: Click to update page data.
Help
: Click to display online help for the page.