Lantronix IONPS6-D ION106 User Guide Rev E - Page 44
C6010, C6120, C6210., recognized. When the chassis powers up
View all Lantronix IONPS6-D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Lantronix ION106-x User Guide 3 major greaterOrEqual 65 false disable 4 critical greaterOrEqual 75 false enable Relay: Type: Scale: Precision: Value: Operation status: Units display: Installed: State: Moduel type: Oper mode: zetta ration 0 6048 ok false dcModule dcModule slave Fan-1: Type: Scale: Precision: Value: Operation status: Units display: rpm units 0 0 ok The data units displayed for Fan 1 in RPM is in units(9) Threshold information: index severity relation value evaluation notifEnable 1 critical equalTo 0 false enable 2 minor greaterThan 2000 false disable 3 major greaterOrEqual 9500 false disable 4 critical greaterOrEqual 9999 false enable Fan-2: Error: Get power operation status no such object. Agent III C1|S23|L1D> Message: Error: Get power operation status no such object. Meaning: indicates that a second fan does not exist; the device is designed with a single fan. Recovery: Information only. No action is required. Message: This is an unmanaged chassis! Meaning: When the ION106-x chassis performed a cold reboot, some layer 2 cards are no longer recognized. When the chassis powers up, the IONMM takes longer to initialize than the TDM cards (C6010, C6120, C6210). Recovery: Upgrade the IONMM and TDM cards to the latest firmware version. 33658 Rev. E https://www.lantronix.com/ 44