Lantronix PremierWave XC HSPA PremierWave XC HSPA+ - User Guide - Page 22

Applications, Protocol Support, Industrial Grade, Temperature Range, Wide Voltage Range

Page 22 highlights

2: Introduction Industrial Grade  Temperature Range: Operating temperature at -40°C to +70°C. Storage temperature at - 40°C to +85°C  Wide Voltage Range: 9 - 30VDC input voltage through locking barrel connector Flexible Connectivity Options  Serial Ports: Two RS-232/422/485 ports with support from 300 to 921 kbps data rate  Ethernet port: Auto-Sensing and Auto MDIX (cross-over) 10/100  Digital Inputs: Two configurable inputs suitable for TTL input levels and tolerant up to 30VDC input voltage  Relay Output: One independently isolated mechanical form-C relay  USB: One USB host port Applications The PremierWave XC HSPA+ intelligent gateway is very suitable for these application scenarios: Remote Monitoring/Control  Data Display Services/Digital Signage  Oil and Gas Exploration  Smart Metering  Street Lighting  Gas Station Pump Control  Irrigation Pump Control  Industrial Controls and Instrumentation  Fixed Telemetry  Railway Maintenance  Food and Beverage Temperature Control  Security and Access Control Panels  In-home Monitoring Out-of-Band Connectivity  Point-of-Sale/Kiosks  Call Boxes Business Continuity Solutions  Primary WAN Link  Secondary WAN Failover/Failback Protocol Support The PremierWave XC HSPA+ intelligent gateway contains a full-featured IP stack. Supported protocols include:  ARP, HTTP, HTTPS, SMTP AUTH, SNMP v1/v2c/v3, UDP/IP, TCP/IP, SSH, SSL, TLS, RSS, UPnP, ICMP, BOOTP, DHCP, Auto IP, Telnet, SNTP, FTP, FTPS, DNS, TFTP, XML and Syslog for network communications and management  FTP and HTTP/HTTPS web server for firmware upgrades and uploading/downloading files  TCP/IP, UDP/IP, Telnet, SSH, SSL, TCP AES and UDP AES for command/response based data acquisition application or alarm triggered connection  HTTP/HTTPS web based monitoring of input readings, chart and data logging  SMTP AUTH, SMS, HTTP/HTTPS Post, FTP/FTPS Put and SNMP Traps for alarm-triggered notification  SNTP and Cellular Network for device clock synchronization PremierWave® XC HSPA+ Intelligent Gateway User Guide 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123

2: Introduction
PremierWave® XC HSPA+ Intelligent Gateway User Guide
22
Industrial Grade
Temperature Range:
Operating temperature at -40°C to +70°C. Storage temperature at -
40°C to +85°C
Wide Voltage Range:
9 - 30VDC input voltage through locking barrel connector
Flexible Connectivity Options
Serial Ports:
Two RS-232/422/485 ports with support from 300 to 921 kbps data rate
Ethernet port:
Auto-Sensing and Auto MDIX (cross-over) 10/100
Digital Inputs:
Two configurable inputs suitable for TTL input levels and tolerant up to 30VDC
input voltage
Relay Output:
One independently isolated mechanical form-C relay
USB:
One USB
host port
Applications
The PremierWave XC HSPA+ intelligent gateway is very suitable for these application scenarios:
Protocol Support
The PremierWave XC HSPA+ intelligent gateway contains a full-featured IP stack. Supported
protocols include:
ARP, HTTP, HTTPS, SMTP AUTH, SNMP v1/v2c/v3, UDP/IP, TCP/IP, SSH, SSL, TLS, RSS,
UPnP, ICMP, BOOTP, DHCP, Auto IP, Telnet, SNTP, FTP, FTPS, DNS, TFTP, XML and
Syslog for network communications and management
FTP and HTTP/HTTPS web server for firmware upgrades and uploading/downloading files
TCP/IP, UDP/IP, Telnet, SSH, SSL, TCP AES and UDP AES for command/response based
data acquisition application or alarm triggered connection
HTTP/HTTPS web based monitoring of input readings, chart and data logging
SMTP AUTH, SMS, HTTP/HTTPS Post, FTP/FTPS Put and SNMP Traps for alarm-triggered
notification
SNTP and Cellular Network for device clock synchronization
Remote Monitoring/Control
Out-of-Band Connectivity
Data Display Services/Digital Signage
Oil and Gas Exploration
Smart Metering
Street Lighting
Gas Station Pump Control
Irrigation Pump Control
Industrial Controls and Instrumentation
Fixed Telemetry
Railway Maintenance
Food and Beverage Temperature Control
Security and Access Control Panels
In-home Monitoring
Point-of-Sale/Kiosks
Call Boxes
Business Continuity Solutions
Primary WAN Link
Secondary WAN Failover/Failback