Lantronix PremierWave XC HSPA PremierWave XC HSPA+ - User Guide - Page 61

To Con Line Settings, Using Web Manager, Table 10-2, Line Command Mode Settings

Page 61 highlights

10: Line and Tunnel Settings Line Settings Xon Char Xoff Char Gap Timer Threshold Description Set Xon Char to be used when Flow Control is set to Software. Prefix decimal with \ or prefix hexadecimal with 0x or prefix a single control character . Set Xoff Char to be used when Flow Control is set to Software. Prefix decimal with \ or prefix hexadecimal with 0x or prefix a single control character . Set the Gap Timer delay to Set the number of milliseconds to pass from the last character received before the driver forwards the received serial bytes. By default, the delay is four character periods at the current baud rate (minimum 1 msec). Set the number of threshold bytes which need to be received in order for the driver to forward received characters. Table 10-2 Line Command Mode Settings Line Command Mode Settings Mode Wait Time Serial String Echo Serial String Signon Message Description Set the Command Mode state of the Line. When in Command Mode, a CLI session operates exclusively on the Line. Choices are:  Always  User Serial String  Disabled Note: In order to enable Command Mode on the Line, Tunneling on the Line must be Disabled (both Connect and Accept modes). Also, custom baud rates are not supported in Command Mode. Enter the amount of time to wait during boot time for the Serial String. This timer starts right after the Signon Message has been sent on the Serial Line and applies only if mode is "Use Serial String". Enter the Text or Binary string of bytes that must be read on the Serial Line during boot time in order to enable Command Mode. It may contain a time element to specify a required delay in milliseconds x, formed as {x}. Applies only if mode is "User Serial String". It may contain a binary character(s) of the form [x]. For example, use decimal [12] or hex [0xc]. Select Enable or Disable for Echo Serial String. Applies only if mode is "User Serial String". Select enable to echo received characters backed out on the line while looking for the serial string. Enter the string of bytes to be sent to the Serial Line during boot time. It may contain a binary character(s) of the form [x]. For example, use decimal [12] or hex [0xc]. To Configure Line Settings Note: The following section describes the steps to view and configure Line 1 settings; these steps apply to other line instances of the device. Using Web Manager  To configure a specific line, click Line in the menu and select Line 1 -> Configuration (Table 10-1). PremierWave® XC HSPA+ Intelligent Gateway User Guide 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123

10: Line and Tunnel Settings
PremierWave® XC HSPA+ Intelligent Gateway User Guide
61
Table 10-2
Line Command Mode Settings
To Configure Line Settings
Note:
The following section describes the steps to view and configure Line 1 settings;
these steps apply to other line instances of the device.
Using Web Manager
To configure a specific line, click
Line
in the menu and select
Line 1 -> Configuration
(
Table
10-1
).
Xon Char
Set Xon Char to be used when Flow Control is set to Software.
Prefix decimal
with \ or prefix hexadecimal with 0x or prefix a single control character
<control>.
Xoff Char
Set Xoff Char to be used when Flow Control is set to Software.
Prefix decimal
with \ or prefix hexadecimal with 0x or prefix a single control character
<control>.
Gap Timer
Set the Gap Timer delay to Set the number of milliseconds to pass from the
last character received before the driver forwards the received serial bytes.
By default, the delay is four character periods at the current baud rate
(minimum 1 msec).
Threshold
Set the number of threshold bytes which need to be received in order for the
driver to forward received characters.
Line Command
Mode Settings
Description
Mode
Set the Command Mode state of the Line.
When in Command Mode, a CLI session
operates exclusively on the Line. Choices are:
Always
User Serial String
Disabled
Note:
In order to enable Command Mode on the Line, Tunneling on the Line must
be Disabled (both Connect and Accept modes). Also, custom baud rates are not
supported in Command Mode.
Wait Time
Enter the amount of time to wait during boot time for the Serial String.
This timer
starts right after the Signon Message has been sent on the Serial Line and applies
only if mode is “Use Serial String”.
Serial String
Enter the Text or Binary string of bytes that must be read on the Serial Line during
boot time in order to enable Command Mode.
It may contain a time element to
specify a required delay in milliseconds x, formed as {x}.
Applies only if mode is
“User Serial String”.
It may contain a binary character(s) of the form [x].
For
example, use decimal [12] or hex [0xc].
Echo Serial String
Select
Enable
or
Disable
for Echo Serial String.
Applies only if mode is “User Serial
String”.
Select enable to echo received characters backed out on the line while
looking for the serial string.
Signon Message
Enter the string of bytes to be sent to the Serial Line during boot time.
It may contain
a binary character(s) of the form [x].
For example, use decimal [12] or hex [0xc].
Line Settings
Description