Lenovo NetVista Hardware Maintenance Manual for NetVista 2289 and 6824 systems - Page 71

Run Flash Recovery using Boot Block., Run Setup. Check Stepping level - bios update

Page 71 highlights

POST Error Code 111 I/O channel parity error 114 Adapter ROM error 129 Internal cache test error 135 Fan failure 151 System board failure 161 Bad CMOS battery 162 Configuration mismatch 163 Date and Time Incorrect 164 Memory Size Error 166 Boot Block Check Sum Error 167 No Processor BIOS Update Found FRU/Action 1. Reseat adapters 2. Any adapter 3. Riser card 4. System Board 1. Adapter Memory 2. System Board 3. Riser card 1. Processor 2. L2 Cache Memory 3. System Board 1. Fan 2. System board 1. System Board 1. Run Setup 2. CMOS Backup Battery (see "Safety information" on page 99) 3. System Board 1. Run Setup and verify Configuration 2. Had a device been added, removed, changed location? If not, suspect that device. 3. Power-on external devices first, then power-on computer 4. CMOS Backup Battery (see "Safety information" on page 99) System Board 5. System Board 1. Time and Date Set 2. CMOS Backup Battery (see "Safety information" on page 99) 3. System Board 1. Run Setup. Check System Summary menu for memory size change. (See "Setup Utility program" on page 12.) 2. Run the Extended Memory Diagnostic tests 1. Run Flash Recovery using Boot Block. See "Flash recovery boot block jumper" on page 95. 2. System Board 1. Run Setup. Check Stepping level for the BIOS level needed, then perform the flash update. 2. Processor Chapter 7. Symptom-to-FRU Index 65

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142

POST Error Code
FRU/Action
111
I/O channel parity error
1.
Reseat adapters
2.
Any adapter
3.
Riser card
4.
System Board
114
Adapter ROM error
1.
Adapter Memory
2.
System Board
3.
Riser card
129
Internal cache test error
1.
Processor
2.
L2 Cache Memory
3.
System Board
135
Fan failure
1.
Fan
2.
System board
151
System board failure
1.
System Board
161
Bad CMOS battery
1.
Run Setup
2.
CMOS Backup Battery (see “Safety
information” on page 99)
3.
System Board
162
Configuration mismatch
1.
Run Setup and verify Configuration
2.
Had a device been added, removed,
changed location? If not, suspect that
device.
3.
Power-on external devices first, then
power-on computer
4.
CMOS Backup Battery (see “Safety
information” on page 99)
System Board
5.
System Board
163
Date and Time Incorrect
1.
Time and Date Set
2.
CMOS Backup Battery (see “Safety
information” on page 99)
3.
System Board
164
Memory Size Error
1.
Run Setup. Check System Summary
menu for memory size change. (See
“Setup Utility program” on page 12.)
2.
Run the Extended Memory Diagnostic
tests
166
Boot Block Check Sum Error
1.
Run Flash Recovery using Boot Block.
See “Flash recovery boot block jumper”
on page 95.
2.
System Board
167
No Processor BIOS Update Found
1.
Run Setup. Check Stepping level for
the BIOS level needed, then perform
the flash update.
2.
Processor
Chapter 7. Symptom-to-FRU Index