Lenovo ThinkPad 390X Hardware Maintenance Manual (November 1999): ThinkPad 390 - Page 56
PC-Doctor DOS Diagnostics Error Codes and Messages, Error Code 0-199, Error Code 1-1 to 1-260 - bios update
View all Lenovo ThinkPad 390X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
PC-Doctor DOS Diagnostics Error Codes and Messages: The following table does not include user-initiated aborts, which display the error type 195. Error Code 0-199 Error Code 0-199 Test(s) Y2K Message Year 2000 issue detected FRU/Action in Sequence: Backup battery (RTC) System board Error Code 1-1 to 1-260 Error Code 1-1 1-34 1-198 1-254 1-255 1-256 1-260 Test(s) SMBUS DMA SMBUS DMA DMA DMA IRQ Message No SMBUS detected (if iFailNoSmbus=1) DMA transfer buffer allocate No SMBUS detected (if iFailNoSmbus=0) DMA transfer DMA page register DMA register IRQ controller FRU/Action in Sequence: System board Error Code 1-286 to 1-300 Error Code 1-286 1-287 1-288 1-292 1-298 1-299 1-300 Test(s) Timer Timer Timer CMOS RAM RTC RTC RTC Message Timer 0 BIOS timer Timer 1 RAM refresh Timer 2 Pattern test Time update Periodic interrupt Alarm interrupt FRU/Action in Sequence: Check BIOS setting Backup battery (RTC) System board 50 ThinkPad 390X / i 1700 HMM