Lexmark XC4143 Printer Languages and Interfaces Technical Reference - Page 98

only The version of the font ROM.

Page 98 highlights

PostScript emulation 98 Key EnableExtraFonts Type Boolean EngineBoot EngineCode EngineSpeed EnvironmentSave string string integer Boolean FactoryDefaults Boolean FatalErrorAddress integer FontResourceDir string FontVersion GenericResourceDir string string GenericResourcePath string Sep InstalledRam integer JobTimeout integer languagelevel integer Definition • True-All 75 resident fonts are enabled. • False-Original 39 PostScript fonts are available. Note: Changes to this parameter take effect when PostScript is restarted. (Read‑only) The version of the boot code. (Read‑only) The version of the engine code. (Read‑only) The maximum speed of the print engine in pages per minute. This parameter indicates or modifies the Resource Save User Default value. Note: When a job changes this parameter from false to true, all interpreter tasks are terminated and restarted at the end of the current job. If set to true and the printer is immediately turned off, then this key causes all non‑volatile parameters to revert to factory default values at the next power‑on. The job that sets FactoryDefaults to true must be the last job executed before power‑off; otherwise, the request is ignored. The address at which a fatal system software error occurred. This address is stored in the parameter FatalErrorAddress before execution is stopped. This address is also transmitted to the host over the communications channel. Specifies the location in the file system for font resource files. Maximum length is 17 characters. (Read‑only) The version of the font ROM. Specifies the location in the file system for resource files. Maximum length is 17 characters. Concatenated to the GenericResourceDir and the category name, and followed by the resource name to get the external location of the resource. Maximum length is 17 characters. (Read‑only) Indicates in bytes the total amount of installed printer memory (RAM) in the system. The value in seconds to which the user parameter JobTimeout is initialized at the beginning of each print job. If you set the system parameter JobTimeout to a negative value, then it is ignored. The previous setting of JobTimeout is used. A value of zero indicates that the timeout is infinite. If you set a number between 1 and 14, then 15 is set. Legal values: x=0, 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

Key
Type
Definition
EnableExtraFonts
Boolean
True—All 75 resident fonts are enabled.
False—Original 39 PostScript fonts are available.
Note:
Changes to this parameter take effect when PostScript is restarted.
EngineBoot
string
(Read
only) The version of the boot code.
EngineCode
string
(Read
only) The version of the engine code.
EngineSpeed
integer
(Read
only) The maximum speed of the print engine in pages per minute.
EnvironmentSave
Boolean
This parameter indicates or modifies the Resource Save User Default value.
Note:
When a job changes this parameter from false to true, all
interpreter tasks are terminated and restarted at the end of the current
job.
FactoryDefaults
Boolean
If set to true and the printer is immediately turned off, then this key causes
all non
volatile parameters to revert to factory default values at the next
power
on. The job that sets FactoryDefaults to true must be the last job
executed before power
off; otherwise, the request is ignored.
FatalErrorAddress
integer
The address at which a fatal system software error occurred. This address
is stored in the parameter FatalErrorAddress before execution is stopped.
This address is also transmitted to the host over the communications
channel.
FontResourceDir
string
Specifies the location in the file system for font resource files. Maximum
length is 17 characters.
FontVersion
string
(Read
only) The version of the font ROM.
GenericResourceDir
string
Specifies the location in the file system for resource files. Maximum length
is 17 characters.
GenericResourcePath
Sep
string
Concatenated to the GenericResourceDir and the category name, and
followed by the resource name to get the external location of the resource.
Maximum length is 17 characters.
InstalledRam
integer
(Read
only) Indicates in bytes the total amount of installed printer memory
(RAM) in the system.
JobTimeout
integer
The value in seconds to which the user parameter JobTimeout is initialized
at the beginning of each print job. If you set the system parameter
JobTimeout to a negative value, then it is ignored. The previous setting of
JobTimeout is used. A value of zero indicates that the timeout is infinite. If
you set a number between 1 and 14, then 15 is set.
Legal values: x=0, 15 <= x <= 65355.
languagelevel
integer
The value of languagelevel integer in systemdict always matches the value
of this system parameter. If set to 2, then the printer behaves as
though /UseOldcopypage and /UseOldfonts are both true. The latter two
parameters return their actual values when queried.
Legal values: 2,3.
PostScript emulation