LiftMaster 3265 3265M Manual - Page 13

STEP 7 Install the Light, STEP 8 Attach the Emergency Release Rope and Handle, Handle - light socket

Page 13 highlights

INSTALLATION STEP 7 Install the Light • Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens. • Install up to a 100 watt maximum light bulb in each socket. Light bulb size should be A19, standard neck only. The light will turn ON and remain lit for approximately 4-1/2 minutes when power is connected. Then the lights will turn OFF. • Reverse the procedure to close the lens. • If the bulbs burn out prematurely due to vibration, replace with a Garage Door Opener bulb. • Use A19, standard neck garage door opener bulbs for replacement. NOTE: Use only standard light bulbs. The use of short neck or speciality light bulbs may overheat the endpanel or light socket. To prevent possible OVERHEATING of the endpanel or light socket: • DO NOT use short neck or specialty light bulbs. • DO NOT use halogen bulbs. Use ONLY incandescent. To prevent damage to the opener: • DO NOT use bulbs larger than 100W. • ONLY use A19 size bulbs. 100 Watt (Max) Release Tab Standard Light Bulb 100 Watt (Max) Standard Light Bulb Lens Hinge INSTALLATION STEP 8 Attach the Emergency Release Rope and Handle • Thread one end of the rope through the hole in the top of the red handle so "NOTICE" reads right side up as shown. Secure with an overhand knot at least 1" (2.5 cm) from the end of the rope to prevent slipping. • Thread the other end of the rope through the hole in the release arm of the outer trolley. • Adjust rope length so the handle is 6 feet (1.83 m) above the floor. Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement. Secure with an overhand knot. NOTE: If it is necessary to cut the rope, heat seal the cut end with a match or lighter to prevent unraveling. To prevent possible SERIOUS INJURY or DEATH from a falling garage door: • If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. • NEVER use emergency release handle unless garage doorway is clear of persons and obstructions. • NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall. Trolley Overhand Knot Rope NOTICE Trolley Release Arm Emergency Release Handle 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

13
INSTALLATION STEP 7
Install the Light
Press the release tabs on both sides of lens. Gently
rotate lens back and downward until the lens hinge is
in the fully open position. Do not remove the lens.
Install up to a 100 watt maximum light bulb in each
socket. Light bulb size should be A19, standard
neck only. The light will turn ON and remain lit
for approximately 4-1/2 minutes when power is
connected. Then the lights will turn OFF.
Reverse the procedure to close the lens.
If the bulbs burn out prematurely due to vibration,
replace with a Garage Door Opener bulb.
Use A19, standard neck garage door opener bulbs for
replacement.
NOTE:
Use only standard light bulbs. The use of short
neck or speciality light bulbs may overheat the endpanel
or light socket.
INSTALLATION STEP 8
Attach the Emergency Release Rope and
Handle
Thread one end of the rope through the hole in the top
of the red handle so “NOTICE” reads right side up as
shown. Secure with an overhand knot at least 1"
(2.5 cm) from the end of the rope to prevent slipping.
Thread the other end of the rope through the hole in
the release arm of the outer trolley.
Adjust rope length so the handle is 6 feet (1.83 m)
above the floor. Ensure that the rope and handle clear
the tops of all vehicles to avoid entanglement. Secure
with an overhand knot.
NOTE:
If it is necessary to cut the rope, heat seal the cut
end with a match or lighter to prevent unraveling.
To prevent possible SERIOUS INJURY or DEATH from
a falling garage door:
If possible, use emergency release handle to
disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced
door could result in an open door falling rapidly
and/or unexpectedly.
NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
NEVER use handle to pull door open or closed. If
rope knot becomes untied, you could fall.
To prevent possible OVERHEATING of the endpanel or
light socket:
DO NOT use short neck or specialty light bulbs.
DO NOT use halogen bulbs. Use ONLY incandescent.
To prevent damage to the opener:
DO NOT use bulbs larger than 100W.
• ONLY use A19 size bulbs.
100 Watt (Max)
Standard Light Bulb
100 Watt (Max)
Standard Light Bulb
Lens
Hinge
Release Tab
NOTICE
Overhand Knot
Trolley Release Arm
Trolley
Emergency
Release Handle
Rope