LiftMaster CSW200UL CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 20

Vac Power Connection, Earth Ground Rod Highly Recommended

Page 20 highlights

110Vac POWER CONNECTION On-Off switch for operator Green Ground Power supply in waterproof conduit. 110Vac Power Wire 1/2 HP and Dual Motor 1 HP 16 Gauge up to 150 FT up to 75 FT Black 110Vac White Neutral Use a 20 amp dedicated circuit for each operator. Input power 120Vac, 60 Hz. Earth Ground Rod Highly Recommended! See previous page. 14 Gauge 250 FT 125 FT 12 Gauge 400 FT 200 FT 10 Gauge 650 FT 325 FT 8 Gauge 1000 FT 500 FT 4 Gauge 2200 FT 1100 FT HEATER POWER CONNECTION Connect the black, white and ground wire from the heater to the 110Vac power supply as shown. When the heater switch is left in the "ON" position, the heater will turn on and off automatically when needed. To reduce the risk of SERIOUS INJURY: DO NOT touch the heater when switch is on, heater may be hot. Switch should left in the "ON" position. Power Supply 18 Green Wires Ground Black Wires 110Vac White Wires Neutral

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

18
110Vac Power Wire
1/2 HP and Dual Motor
1 HP
16 Gauge
up to 150 FT
up to 75 FT
14 Gauge
250 FT
125 FT
12 Gauge
400 FT
200 FT
10 Gauge
650 FT
325 FT
8 Gauge
1000 FT
500 FT
4 Gauge
2200 FT
1100 FT
110Vac POWER CONNECTION
HEATER POWER CONNECTION
Earth Ground Rod Highly Recommended!
See previous page.
Use a 20 amp dedicated circuit for each operator.
Input power 120Vac, 60 Hz.
On-Off switch for operator
Green Ground
Black 110Vac
White Neutral
Green Wires Ground
Black Wires 110Vac
White Wires Neutral
Power supply in
waterproof conduit.
Power
Supply
Connect the black, white and ground wire from the heater to the 110Vac power supply as shown. When the heater switch is left in the
ON
” position, the heater will turn on and off automatically when needed.
Switch should left in the
ON
” position.
To reduce the risk of SERIOUS INjURY:
DO NOT touch the heater when switch is
on, heater may be hot.