TROUBLESHOOTING HYDRAULIC DON'TS 1. DO NOT use only one wrench to lighten hose swivel fittings. Use two wrenches, one to tighten and one to hold back opposite fitting. See illustration above. 2. DO NOT pour detergent oil, mineral spirits, diesel fuel, fuel oil or gasoline into the tank. NEVER USE BRAKE FLUID. Only use hydraulic oil. 3. DO NOT put pipe dope or teflon tape on any part of hose fittings. 4. DO NOT remove vent cap except to fill tank with fluid. 5. DO NOT attach hoses to fittings that have dirt on them. Clean hoses, fittings and fitting seats carefully. HOSES REMOVAL NOTE: Wear adequate eye protection when performing this step. To minimize loss of fluid when removing hoses, remove power, position bypass valve to manual operation, and press and hold directional valve manual override for about 30 seconds. You will need to insert a small tool into hole and push, to activate manual override. HYDRAULIC PUMP DIRECTIONAL VALVE CONNECTORS (2) One for open direction and one for closed direction. IMPORTANT: In directional valve solenoid (DV-1) the two brown wires attach to terminals #1 and #2 in the connector. In directional valve solenoid (DV-2) the two purple wires attach to terminals #1 and #2 in the connector. Directional Valve Wiring Assembly Directional Valve Manual Override R.H. CLOSE Direction Must Be Clean, No Pipe Dope One Wrench To Hold This Fitting One Wrench To Tighten This Fitting Manual Override R.H. OPEN Direction Vent Cap (add fluid here) Relief Valve Built-In Bypass Valve Handle Directional Valve Override (DV-2) Directional Valve Override (DV-1) 29 Port "A" Port "B" From Drive Motor

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

29
HYDRAULIC DON’TS
1.
DO NOT
use only one wrench to lighten hose swivel fittings.
Use two wrenches, one to tighten and one to hold back
opposite fitting. See illustration above.
2.
DO NOT
pour detergent oil, mineral spirits, diesel fuel, fuel oil
or gasoline into the tank.
NEVER USE BRAKE FLUID.
Only use
hydraulic oil.
3.
DO NOT
put pipe dope or teflon tape on any part of hose
fittings.
4.
DO NOT
remove vent cap except to fill tank with fluid.
5.
DO NOT
attach hoses to fittings that have dirt on them. Clean
hoses, fittings and fitting seats carefully.
HOSES REMOVAL
NOTE:
Wear adequate eye protection when performing this step.
To minimize loss of fluid when removing hoses, remove power,
position bypass valve to manual operation, and press and hold
directional valve manual override for about 30 seconds.
You will need to insert a small tool into hole and push, to activate
manual override.
HYDRAULIC PUMP DIRECTIONAL VALVE CONNECTORS
(2) One for open direction and one for closed direction.
IMPORTANT:
In directional valve solenoid (DV-1) the two brown wires attach to
terminals #1 and #2 in the connector.
In directional valve solenoid (DV-2) the two purple wires attach to
terminals #1 and #2 in the connector.
TROUBLESHOOTING
Must Be Clean,
No Pipe Dope
One Wrench To
Hold This Fitting
One Wrench To
Tighten This Fitting
Manual Override
R.H. OPEN Direction
Manual Override
R.H. CLOSE Direction
Directional Valve
Directional Valve
Wiring Assembly
Relief Valve
Built-In
Vent Cap
(add fluid here)
Port “A”
Port “B”
From Drive Motor
Directional Valve
Override (DV-1)
Bypass Valve
Handle
Directional Valve
Override (DV-2)