LiftMaster MGJ MGJ Manual - Page 4

Operator Specifications, THE 3 BUTTON CONTROL STATION IS OUT OF SIGHT OF DOOR

Page 4 highlights

OPERATOR SPECIFICATIONS MOTOR TYPE Limited Duty HORSEPOWER MGJ: 1/2 HP 1 or 3 Phase MGJ: 3/4 HP 1 Phase (only) MGH: 1/2 & 3/4Hp 1 Phase VOLTAGE MGJ: 120V, 60Hz, 1Ph 230V, 50 or 60Hz, 3Ph 230V, 60Hz, 1Ph 380V, 50Hz, 3Ph 460V, 60Hz, 3Ph MGH: 120V, 60Hz, 1Ph CURRENT: See motor nameplate The rate of operation shall not exceed 12 cycles of opening and closing per hour. ELECTRICAL TRANSFORMER 24VAC CONTROL STATION NEMA 1 three button station. OPEN/CLOSE/STOP WIRING TYPE MGH/MGJ: C2 (factory default), B2 optional LIMIT ADJUST Linear driven, fully adjustable screw type cams. Adjustable to 18 feet. MECHANICAL DRIVE REDUCTION 45:1 Reduction (Heavy duty wormgear-in-oil-bath speed reducer) OUTPUT SPROCKET Size #41 OUTPUT SHAFT SPEED MGJ: 1Ph, 23RPM 3Ph, 39RPM MGH: 1Ph, 23RPM BEARINGS Heavy duty wormgear-in-oilbath speed reducer. DUTY 12 Cycles per Hour max 50 Cycles per Day max DOOR SPEED 9" per second, typical, depending on door. MAX. DOOR HEIGHT 1/2 HP = 14' 3/4 HP = 18' SAFETY DISCONNECT Floor level disconnect for emergency manual door operation. REVERSING EDGE (Optional Electric or pneumatic sensing device attached to the bottom edge of door A REVERSING EDGE IS STRONGLY RECOMMENDED FOR ALL COMMERCIAL OPERATOR INSTALLATIONS. REQUIRED WHEN THE 3 BUTTON CONTROL STATION IS OUT OF SIGHT OF DOOR OR ANY OTHER CONTROL (AUTOMATIC OR MANUAL) IS USED. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

MOTOR
TYPE:
. . . . . . . . . . . . . . . . . . .Limited Duty
HORSEPOWER:
. . . . . . . . . . .
MGJ:
1/2 HP 1 or 3 Phase
MGJ:
3/4 HP 1 Phase (only)
MGH:
1/2 & 3/4Hp 1 Phase
VOLTAGE:
. . . . . . . . . . . . . . . .
MGJ:
120V, 60Hz, 1Ph
230V, 50 or 60Hz, 3Ph
230V, 60Hz, 1Ph
380V, 50Hz, 3Ph
460V, 60Hz, 3Ph
MGH:
120V, 60Hz, 1Ph
CURRENT:
See motor nameplate
The rate of operation shall not exceed 12 cycles of opening
and closing per hour.
MECHANICAL
DRIVE REDUCTION:
. . . . . . . . . . .
45:1 Reduction
(Heavy duty wormgear-in-oil-bath speed reducer)
OUTPUT SPROCKET:
. . . . . . . . . .
Size #41
OUTPUT SHAFT SPEED:
. . . . . . . .
MGJ:
1Ph, 23RPM
3Ph, 39RPM
. . . . . . . . . . . . . . . . . . . . . . . . . . .
MGH:
1Ph, 23RPM
BEARINGS:
. . . . . . . . . . . . . . . . . .
Heavy duty wormgear-in-oil-
bath speed reducer.
DUTY:
. . . . . . . . . . . . . . . . . . . . . .
12 Cycles per Hour max
50 Cycles per Day max
DOOR SPEED:
. . . . . . . . . . . . . . . .
9" per second, typical,
depending on door.
MAX. DOOR HEIGHT:
. . . . . . . . . .
1/2 HP = 14'
3/4 HP = 18'
SAFETY
DISCONNECT:
. . . . . . . . . . . . . . . . . . . . Floor level disconnect for
emergency manual door operation.
REVERSING EDGE (Optional):
. . . . . . .
Electric or
pneumatic
sensing device attached to the bottom edge of door
A REVERSING EDGE IS STRONGLY RECOMMENDED FOR ALL
COMMERCIAL OPERATOR
INSTALLATIONS. REQUIRED
WHEN
THE 3 BUTTON CONTROL STATION IS OUT OF SIGHT OF DOOR
OR ANY OTHER CONTROL (AUTOMATIC OR MANUAL) IS USED.
ELECTRICAL
TRANSFORMER:
. . . . . . . . . . 24VAC
CONTROL STATION:
. . . . . . .
NEMA 1 three button station.
OPEN/CLOSE/STOP
WIRING TYPE:
. . . . . . . . . . .
MGH/MGJ:
C2 (factory default), B2
optional
LIMIT ADJUST:
. . . . . . . . . . .
Linear driven, fully adjustable
screw type cams. Adjustable to
18 feet.
OPERATOR SPECIFICATIONS