LiftMaster RSW12V RSW12V Install Manual - Page 12

Caution, Suggestion, Example

Page 12 highlights

INSTALLATION » STANDARD INSTALLATION POSITION THE GATE BRACKET SAMPLE STANDARD INSTALLATION IS SHOWN ON PREVIOUS PAGE. Gate Hinge Center OUT A OUT IN IN B E Long Arm Short Arm C D D MINUS 10" 10" DISTANCE DISTANCE Wall Concrete Pad Dimension (A) thru (E) are from the center of one pivot point to the center of another pivot point. Caution: If the gate is longer than 18 feet, follow CHART A: A-2. Suggestion: The dimensions between the gate and the concrete pad is always 10 inches less than the dimension D. Example: D = 42", if the dimensions between the gate and the concrete pad is 32". DISTANCE If this dimension is between 20 and 32 inches, a compact installation is necessary. Refer to following page. CHART A CHART B ABCDE ABCDE 1 46" 35.5" 29.5" 35" 11" 45" 1 34.5" 34.75" 29.5" 35" 14" 43" 2 46.75" 35.5" 33.5" 42" 11" 37" 2 44" 36.5" 32.5" 42" 14" 32" 3 46.75" 37" 31.5" 40" 11" 41" 3 44" 37" 30.5" 40" 14" 40" 4 47.25" 37.25" 30" 37" 11" 45" 4 45" 37" 30.5" 37" 14" 43" 5 47" 35" 29.5" 32" 11" 45" 5 44.75" 35.75" 29.5" 32" 14" 44" 6 42.5" 33" 26.5" 28.5" 11" 41" 6 41" 39" 27.5" 28.5" 14" 41" PROCEED TO PAGE 14. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

11
1
2
3
4
5
6
34.5"
44"
44"
45"
44.75"
41"
34.75"
36.5"
37"
37"
35.75"
39"
29.5"
32.5"
30.5"
30.5"
29.5"
27.5"
35"
42"
40"
37"
32"
28.5"
14"
14"
14"
14"
14"
14"
43"
32"
40"
43"
44"
41"
A
B
C
D
E
1
2
3
4
5
6
46"
46.75"
46.75"
47.25"
47"
42.5"
35.5"
35.5"
37"
37.25"
35"
33"
29.5"
33.5"
31.5"
30"
29.5"
26.5"
35"
42"
40"
37"
32"
28.5"
11"
11"
11"
11"
11"
11"
45"
37"
41"
45"
45"
41"
A
B
C
D
E
DISTANCE
DISTANCE
INSTALLATION
ยป STANDARD INSTALLATION
Dimension (
A
) thru (
E
) are from the center of one pivot point to the center of another pivot point.
PROCEED TO PAGE 14.
POSITION THE GATE BRACKET
Gate Hinge Center
A
B
C
E
OUT
IN
Short Arm
Long Arm
Concrete Pad
OUT
IN
D
D MINUS 10"
10"
Wall
DISTANCE
If this dimension is
between 20 and 32
inches, a compact
installation is necessary.
Refer to following page.
SAMPLE STANDARD INSTALLATION IS SHOWN ON PREVIOUS PAGE.
Caution:
If the gate is longer than 18 feet, follow
CHART A:
A-2
.
Suggestion:
The dimensions between the gate and the concrete pad is always 10 inches less than the dimension D.
Example:
D = 42", if the dimensions between the gate and the concrete pad is 32".
CHART A
CHART B