LiftMaster RSW12V RSW12V Install Manual - Page 9

Introduction - control board

Page 9 highlights

INTRODUCTION » OPERATOR SPECIFICATIONS + CARTON INVENTORY + HARDWARE INVENTORY OPERATOR SPECIFICATIONS This model is intended for use in vehicular swing gate applications: Gate Classifications: Main Supply (Motor): Accessory Power: Current Consumption: Battery Charger Supply: Heater Draw (Optional): Main AC Supply: DC Absorbed Power: Solar Power Max: Maximum Gate Weight/Length: Daily Cycle Rate using transformer power: Maximum Gate Travel Range: Temperature: Control Board Fuse: CLASS I & II 12 Vdc 12 V nominal Class II battery voltage source is limited to: • Solar or AC Cable up to 50 feet - 500 mA • AC Cable 50 feet up to 250 feet - 250 mA • AC Cable 250 feet up to 1000 feet - 100 mA NOTE: Increased accessory power drawn from the operator will shorten the battery life. 5 Amps at 120 Vac 13.5 Vac, 30 Va, Direct Plug in Power Supply, Class II Compliant 325 watts 120 Vac 2 Amps 12 V at 30 watts max. 400 lbs. / 16 ft. long 600 lbs. / 12 ft. long 700 lbs. / 10 ft. long 800 lbs. / 8 ft. long 1000 lbs. / 6 ft. long 250 cycles/day 115 degrees -20°C to 40°C (-4°F to 104°F) without Heater -40°C to 40°C (-40°F to 104°F) with Heater 30 Amp (2) 27.66" 17" SIDE VIEW 13.6" FRONT VIEW MOUNTING FOOTPRINT 14" 12.2" 13.6" 17" CARTON INVENTORY • Operator • Operator arm assembly • Transformer • Documentation Packet • Battery 12 Vdc 7AH (1) • Keys (2) HARDWARE INVENTORY • Warning Signs (2) • Warranty Card 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

8
INTRODUCTION
» OPERATOR SPECIFICATIONS + CARTON INVENTORY + HARDWARE INVENTORY
OPERATOR SPECIFICATIONS
This model is intended for use in vehicular swing gate applications:
Gate Classifications:
CLASS I & II
Main Supply (Motor):
12 Vdc
Accessory Power:
12 V nominal Class II battery
voltage source is limited to:
Solar or AC Cable up to
50 feet - 500 mA
AC Cable 50 feet up to
250 feet - 250 mA
AC Cable 250 feet up to
1000 feet - 100 mA
NOTE:
Increased accessory power drawn from
the operator will shorten the battery life.
Current Consumption:
5 Amps at 120 Vac
Battery Charger Supply:
13.5 Vac, 30 Va, Direct Plug in
Power Supply, Class II Compliant
Heater Draw (Optional):
325 watts
Main AC Supply:
120 Vac
DC Absorbed Power:
2 Amps
Solar Power Max:
12 V at 30 watts max.
Maximum Gate
Weight/Length:
400 lbs. / 16 ft. long
600 lbs. / 12 ft. long
700 lbs. / 10 ft. long
800 lbs. / 8 ft. long
1000 lbs. / 6 ft. long
Daily Cycle Rate using
transformer power:
250 cycles/day
Maximum Gate
Travel Range:
115 degrees
Temperature:
-20°C to 40°C (-4°F to 104°F)
without Heater
-40°C to 40°C (-40°F to 104°F)
with Heater
Control Board Fuse:
30 Amp (2)
CARTON INVENTORY
• Operator
• Operator arm assembly
• Transformer
• Documentation Packet
• Battery 12 Vdc 7AH (1)
• Keys (2)
HARDWARE INVENTORY
• Warning Signs (2)
• Warranty Card
SIDE VIEW
FRONT VIEW
13.6"
27.66"
17"
MOUNTING FOOTPRINT
14"
12.2"
13.6"
17"