LiftMaster TLS1CARD Owners Manual - English - Page 4
Tcp Mode 2
View all LiftMaster TLS1CARD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
TCP MODE 2 TCP (TRAFFIC CONTROL MODE WITH PRE-WARNING) MODE 2 This mode is intended as a special input to open the door without activating the TImer-to-Close (TTC) while any other open signal will activate the TTC with Pre-Warning. It provides dry contact control based on the position/movement of the door and the TTC status. The relays can be used with or without the timers programmed. An open signal from the standard push button or radio input would not re-enable the timer if the special input to open has been enabled. This mode would be used in lieu of previous modification 90-T2. 1 Disconnect power to the operator. 2 Turn DIP switch 4 on the TLS1CARD to the ON position. All other DIP switches should remain OFF. TCP MODE 2 DIP SWITCH SETTINGS O1 2 3 4 N 3 Connect the auxiliary device(s) to the input and output terminals on the TLS1CARD as described below. Outputs: • Connect a red light to the R1 terminals on the TLS1CARD. This will signal the door is about to close. • Connect a green light to the R2 terminals on the TLS1CARD. This will signal that the door is fully open. • Connect an audio/visual signalling device to the R3 terminals on the TLS1CARD. This will signal that the door has been opened by the special input to open (SIO) and the timer is not enabled. Inputs: • Connect a push button, keyswitch, etc. to the SIO input terminals. This will open the door without enabling the TTC. • If the application warrants the use of Timer Secure mode at some times and Timer modes at other times, set the operator selector dial to TS and make a connection to the T/TS input. The input should have a latched contact, such as a 2-position maintained keyswitch to switch between TS and T. Fully Open Timer Stage 1 (OLS) (OLS Only) Timer Stage 2 (Pre-Warning) (OLS, OMS, & USP Only) Closing Fully Closed Opening (CLS) Undefined Open Mid-Stop Reversing from Stopped (OMS) Obstruction Position (USP) R1 LED OFF OFF ON OFF OFF OFF OFF OFF OFF R2 LED ON ON OFF OFF OFF OFF OFF OFF OFF R3 LED ON* OFF OFF OFF OFF ON* ON* ON* OFF NOTES: • Relay LEDs R1, R2, and R3 on the TLS1CARD will turn ON at the same time as relays R1, R2, and R3. • * R3 turns ON as soon as SIO is enabled and remains ON until closing begins. TCP MODE 2 (TYPICAL CONNECTION) Horn/Strobe Green Red N.O. Comm N.O. Comm N.O. Comm 6 5 R3 T/TS 12 FD/SIS 11 INPUTS (RELAYS) OUTPUTS 4 R2 3 COMMON 10 SIC 9 2 R1 1 SIO 8 COMMON 7 5 A, 230 Vac, 30 Vdc Dry Contact Only TLS1CARD Timer Light Status Option Card 40-35757-1 2-Position Maintained Switch Momentary Push Button After configurations and connections have been made for your card mode proceed to Installation page 10. 4