TCP MODE 3 TCP (TRAFFIC CONTROL MODE WITH PRE-WARNING) MODE 3 This mode is intended to control auxiliary devices connected to relays R1, R2, and R3. It provides dry contact control based on the position/movement of the door and the Timer-to-Close (TTC) status. It also incorporates an adjustable TTC plus a separately adjustable Pre-Warning. The relays can be used with or without the timers programmed. This mode would be used in lieu of previous modification 90-T4. 1 Disconnect power to the operator. 2 Turn DIP switch 3 on the TLS1CARD to the ON position. All other DIP switches should remain OFF. TCP MODE 3 DIP SWITCH SETTINGS O1 2 3 4 N 3 Connect the auxiliary device(s) to the input and output terminals on the TLS1CARD as described below. Outputs: • Connect a red light to the R1 terminals on the TLS1CARD. This will signal the door is about to close. • Connect a green light to the R2 terminals on the TLS1CARD. This will signal that the door is fully open or at the open mid-stop position. • Connect an audio/visual signalling device to the R3 terminals on the TLS1CARD. This will signal that the door is in motion. Inputs: • If the application warrants the use of Timer Secure mode at some times and Timer modes at other times, set the operator selector dial to TS and make a connection to the T/TS input. The input should have a latched contact, such as a 2-position maintained keyswitch to switch between TS and T. R1 LED R2 LED R3 LED Fully Open Timer Stage 1 (OLS) (OLS & OMS Only) Timer Stage 2 (Pre-Warning) (OLS, OMS, & USP Only) OFF OFF ON ON ON OFF OFF OFF OFF Closing Fully Closed Opening (CLS) OFF OFF OFF OFF OFF OFF ON OFF ON Undefined Open Mid-Stop Reversing from Stopped (OMS) Obstruction Position (USP) OFF OFF OFF OFF ON OFF OFF OFF ON NOTES: • Relay LEDs R1, R2, and R3 on the TLS1CARD will turn ON at the same time as relays R1, R2, and R3. • During timer stages 1 and 2 the relays shown are only ON/OFF when the door is positioned as shown in parenthesis. The selector dial on the operator would be set to T, TS, or FSTS. TCP MODE 3 (TYPICAL CONNECTION) Horn/Strobe Green Red N.O. Comm N.O. Comm N.O. Comm 6 R3 5 T/TS 12 FD/SIS 11 INPUTS (RELAYS) OUTPUTS 4 R2 3 COMMON 10 SIC 9 2 R1 1 SIO 8 COMMON 7 5 A, 230 Vac, 30 Vdc Dry Contact Only TLS1CARD Timer Light Status Option Card 40-35757-1 2-Position Maintained Switch After configurations and connections have been made for your card mode proceed to Installation page 10. 5