LiftMaster TLS1CARD Owners Manual - English - Page 6
Tcp Mode 4
View all LiftMaster TLS1CARD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
TCP MODE 4 TCP (TRAFFIC CONTROL MODE WITH PRE-WARNING) MODE 4 This mode is intended to control auxiliary devices connected to relays R1 and R2, with optional flashing for relay R1. It also incorporates an adjustable Timer-to-Close (TTC) plus a separately adjustable Pre-Warning. The relays can be used with or without the timers programmed. This mode would be used in lieu of previous modification 90-RGLFCIR or 90-HDFLASH2. 1 Disconnect power to the operator. TCP MODE 4 DIP SWITCH SETTINGS 2 Turn DIP switch 3 and 4 on the TLS1CARD to the ON position. DIP switches 1 and 2 should remain OFF. O1 2 3 4 N 3 Connect the auxiliary device(s) to the input and output terminals on the TLS1CARD as described below. Outputs: • Connect a red light to the R1 terminals on the TLS1CARD. This will signal the door is about to close or is closing. • Connect a green light to the R2 terminals on the TLS1CARD. This will signal that the door is fully open. Inputs: • If the application warrants the use of Timer Secure mode at some times and Timer modes at other times, set the operator selector dial to TS and make a connection to the T/TS input. The input should have a latched contact, such as a 2-position maintained keyswitch to switch between TS and T. • If the application requires the ability to turn off the flash feature, connect a selector switch to the FD/SIS input terminals for a flasher defeat. The input device should have a latched contact, such as a 2-position maintained keyswitch. A jumper wire can also be used to disable the flash function. Fully Open Timer Stage 1 (OLS) (OLS Only) Timer Stage 2 (Pre-Warning) (OLS, OMS, & USP Only) Closing Fully Closed Opening (CLS) R1 LED OFF R2 LED ON R3 LED OFF OFF ON or Flash ON or Flash OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF Undefined Open Mid-Stop Reversing from Stopped (OMS) Obstruction Position (USP) OFF OFF OFF OFF OFF OFF OFF OFF OFF NOTES: • Relay LEDs R1, R2, and R3 on the TLS1CARD will turn ON at the same time as relays R1, R2, and R3. • During timer stages 1 and 2 the relays shown are only ON/OFF when the door is positioned as shown in parenthesis. The selector dial on the operator would be set to T, TS, or FSTS. TCP MODE 4 (TYPICAL CONNECTION) Green Red N.O. Comm N.O. Comm 6 R3 5 T/TS 12 FD/SIS 11 INPUTS (RELAYS) OUTPUTS 4 R2 3 COMMON 10 SIC 9 2 R1 1 SIO 8 COMMON 7 5 A, 230 Vac, 30 Vdc Dry Contact Only TLS1CARD Timer Light Status Option Card 40-35757-1 2-Position Maintained Switch After configurations and connections have been made for your card mode proceed to Installation page 10. 6