MSI P55 GD80 User Guide - Page 39
DDR voltage: measure the current DDR voltage
UPC - 816909062380
View all MSI P55 GD80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
MS-7581 Voltage Check Point: V_Check Point This voltage check point set is used to measure the current CPU/ CPU_VTT/ DDR/ PCH voltage. CPU_VTT PCH GND CPU DDR GND CPU voltage: measure the current CPU voltage with CPU point and GND point by using a mul- timeter. CPU GND CPU_VTT voltage: measure the current CPU_ VTT voltage with CPU_VTT point and GND CPU_VTT GND point by using a multimeter. DDR GND DDR voltage: measure the current DDR voltage with DDR point and GND point by using a multimeter. PCH voltage: measure the current PCH voltage with PCH point and GND point by using a mul- timeter. PCH GND 2-23
2-23
MS-7581
Voltage Check Po±nt: V_Check Po±nt
Th±s voltage check po±nt set ±s used to measure the current CPU/ CPU_VTT/ DDR/
PCH voltage.
CPU
CPU_VTT
DDR
PCH
GND
GND
CPU
GND
CPU voltage: measure the current CPU voltage
w±th CPU po±nt and GND po±nt by us±ng a mul-
t±meter.
CPU_VTT
GND
CPU_VTT voltage: measure the current CPU_
VTT voltage w±th CPU_VTT po±nt and GND
po±nt by us±ng a mult±meter.
DDR
GND
DDR voltage: measure the current DDR voltage
w±th DDR po±nt and GND po±nt by us±ng a mul-
t±meter.
PCH
GND
PCH voltage: measure the current PCH voltage
w±th PCH po±nt and GND po±nt by us±ng a mul-
t±meter.