Reassembly for high performance
View all Makita XLC02ZB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
Example 4: Prefilter's securing lip is not firmly locked into groove of cleaner housing 1 3 2 ► 1 . Groove of cleaner housing 2. Prefilter 3. Securing lip ► 1 . O Mark Reassembly for high performance filter Connect high performance filter. At this time, make sure to twist high performance filter so that securing lip is firmly locked into cleaner unit. 1 1 2 1 2 ► 1 . High performance filter 2. Securing lip ► 1 . Handle 2. Capsule NOTE: • Always remove dust ahead of time, as suction power will be reduced if there is too much dust in cleaner. • Always be sure to check that high performance filter is loaded correctly prior to using cleaner. If they are not loaded correctly, dust will get into the motor housing, and cause motor failure. If the following examples occur, high performance filter is not loaded correctly. Reload them correctly to rectify problem. Problem Examples Securing lip of high performance filter is not firmly locked into groove of cleaner housing. 1 ► 1 . Securing lip Connect capsule. Align O symbol on capsule with O symbol on handle and then firmly twist capsule in direction of arrow until it is secured. 1 2 ► 1 . Securing lip 2. Groove of cleaner housing 9 ENGLISH