Marantz AV7701 AV7701 - User Guide - Page 100

Dual backup memory function, Panel lock function, Disabling all key button operations - back panel

Page 100 highlights

Basic version Dual backup memory function The unit stores settings information in nonvolatile memory even when the main power supply is turned off. Using the Dual Backup Memory function, you can write settings information to another memory area to back up saved settings for recovery anytime as needed. Remembering set details (Backup). BACK Panel lock function To prevent accidental operation of this unit, you can disable operation of the buttons on the front panel. BACK ui ENTER Advanced version Information DISPLAY ZONE SELECT nnRemembering set details (Backup) Set the unit in the state you want remembering, and press and hold DISPLAY and ZONE SELECT for at least 3 seconds. "MEMORY SAVING" is shown in the display, and the setting details are remembered. NOTE • The volume is not remembered. • If remembered details are overwritten, the previously remembered contents are deleted. nnRecalling remembered details (Recovery) Press and hold BACK and ZONE SELECT together for at least 3 seconds. "MEMORY LOAD" is shown in the display, and the remembered details are recalled. NOTE • If there is no remembered data, "NO BACKUP" is shown in the display, and no remembered details are recalled. • As the volume cannot be recalled, it returns to the factory setting volume. X ON/STANDBY nnDisabling all key button operations 1 Press X ON/STANDBY while you press and hold BACK and ENTER with the unit in standby mode. 2 Press ui to select "FP/VOL LOCK ON". 3 Press ENTER to enter the setting. All button operations except X ON/STANDBY are disabled. nnDisabling all button operations except VOLUME 1 Press X ON/STANDBY while you press and hold BACK and ENTER with the unit in standby mode. 2 Press ui to select "FP LOCK ON". 3 Press ENTER to enter the setting. All button operations except X ON/STANDBY and VOLUME are disabled. v See overleaf DVD 97

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186

97
Panel lock function
To prevent accidental operation of this unit, you can disable operation of the buttons on the front panel.
X
ON/STANDBY
BACK
ui
ENTER
n
Disabling all key button operations
1
Press
X
ON/STANDBY
while you press and hold
BACK
and
ENTER
with the unit
in standby mode.
2
Press
ui
to select “FP/VOL LOCK ON”.
3
Press
ENTER
to enter the setting.
All button operations except
X
ON/STANDBY
are disabled.
n
Disabling all button operations except VOLUME
1
Press
X
ON/STANDBY
while you press and hold
BACK
and
ENTER
with the unit
in standby mode.
2
Press
ui
to select “FP LOCK ON”.
3
Press
ENTER
to enter the setting.
All button operations except
X
ON/STANDBY
and
VOLUME
are disabled.
Dual backup memory function
The unit stores settings information in nonvolatile memory even when the main power supply is turned
off. Using the Dual Backup Memory function, you can write settings information to another memory area
to back up saved settings for recovery anytime as needed. Remembering set details (Backup).
BACK
DISPLAY
ZONE SELECT
n
Remembering set details (Backup)
Set the unit in the state you want remembering, and press and hold
DISPLAY
and
ZONE
SELECT
for at least 3 seconds.
“MEMORY SAVING” is shown in the display, and the setting details are remembered.
NOTE
The volume is not remembered.
If remembered details are overwritten, the previously remembered contents are deleted.
n
Recalling remembered details (Recovery)
Press and hold
BACK
and
ZONE SELECT
together for at least 3 seconds.
“MEMORY LOAD” is shown in the display, and the remembered details are recalled.
NOTE
If there is no remembered data, “NO BACKUP” is shown in the display, and no remembered details are
recalled.
As the volume cannot be recalled, it returns to the factory setting volume.