48. Power supply cord-Plug into a grounded 3 prong outlet INSTALL ACCESS PANELS 50. Reinstall access panels and fasteners Insulation (on some models) Plug into a grounded 3 prong outlet. 49. Reconnect power Reconnect electrical power at the fuse box or circuit breaker box. NOTE: With the access panel off, start the dishwasher and allow it to complete the shortest Installation Cycle while checking unit for leaks. See instructions on this manual under Check Operations section. CHECK OPERATION ■ Read the dishwasher Quick Start Guide that came with your dishwasher. ■ Check that all parts have been installed and no steps were skipped. Check that you have used all tools. ■ Run the Installation Cycles as follows (Note that it can be beneficial to run this with the access panel removed in order to look for presence of water under the unit. If running in this state, the float switch wire MUST still be connected to the float switch.) ■ If the dishwasher is not working properly, disconnect power or unplug dishwasher and refer to the "If Dishwasher Does Not Operate" section. ■ Press any 3 keys (except Delay or Cancel) in the sequence 1-2-3-1-2-3-1-2-3 with no more than 1 second between key presses to enter the Installation cycle then press button #2. ■ Close the door and the cycle will start. ■ All LEDs turn on immediately upon receiving entry sequence. ■ A tone may play depending on the model. ■ The cycle will pause when the door is opened and resume when closed. ■ No Start/Resume key press required to resume. ■ The installation cycle may last several minutes. ■ Press Cancel key to exit installation cyle mode. The product will exit this mode after 10 minutes or if power is removed from the appliance. ■ If any error codes or blinking lights are found, see Error Code section in this Manual prior to calling for service. NOTE: It is normal for the drain pump to sound loud upon the first run since no water is present in the system. Place the toe panel behind the access panel against the dishwasher leg. If insulation is included on this model, make sure insulation does not interfere with the float assembly. Push the access panel up toward the top of the product so that it hangs on the hooks on the plastic side members. ■ Reinstall the toe/access panel assy.With side shield to go between the toe/access panel assembly and the side member. Align the rectangular slot in the foam and assembly the toe/ access panel assembly to the unit using the screw. NOTE: Remove film on door Score around door for easier removal. 51. Check access panel edge Numeric Display Approximate interval Time Machine Action All LEDs on 0:01 1 0:30 (Maximum 5:00) Pause Initial Drain 2 2:00 Fill 3.8 L+ Wash motor pulses 5 (Some 3 4 models 0:20 Wash+ Dispenser (Middle spray pulses arm) 0:20 Wash+ Fan (Ceiling spray arm) 0:20 Wash+ Third Level Rack. If present in this model 6 0:30 Wash+ Heater (Lower spray arm) 7 1:00 (Maximum 5:00) Drain Pracess Check that the lower edge of the access panel touches the floor. Adjust if necessary. 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

27
48.
Power supply cord—Plug into
a grounded 3 prong outlet
Plug into a grounded 3 prong outlet.
49.
Reconnect power
Reconnect electrical power at the fuse box or circuit
breaker box.
NOTE:
With the access panel off, start the dishwasher and allow
it to complete the shortest Installation Cycle while checking unit
for leaks
. See instructions on this manual under Check Operations
section.
CHECK OPERATION
Read the dishwasher Quick Start Guide that came with your
dishwasher.
Check that all parts have been installed and no steps were
skipped. Check that you have used all tools.
Run the Installation Cycles as follows (Note that it can be
beneficial to run this with the access panel removed in order
to look for presence of water under the unit. If running in this
state, the float switch wire MUST still be connected to the float
switch.)
If the dishwasher is not working properly, disconnect power
or unplug dishwasher and refer to the “If Dishwasher Does Not
Operate” section.
Press any 3 keys (except Delay or Cancel) in the sequence
1-2-3-1-2-3-1-2-3 with no more than 1 second between key
presses to enter the Installation cycle then press button #2.
Close the door and the cycle will start.
All LEDs turn on immediately upon receiving entry sequence.
A tone may play depending on the model.
The cycle will pause when the door is opened and resume
when closed.
No Start/Resume key press required to resume.
The installation cycle may last several minutes.
Press Cancel key to exit installation cyle mode. The product
will exit this mode after 10 minutes or if power is removed from
the appliance.
If any error codes or blinking lights are found, see Error Code
section in this Manual prior to calling for service.
NOTE:
It is normal for the drain pump to sound loud upon the
first run since no water is present in the system.
Numeric
Display
All
LEDs
on
1
2
3
4
5
(Some
models
6
7
Approximate
interval
Time
0:01
0:30
(Maximum
5:00)
2:00
0:20
0:20
0:20
0:30
1:00
(Maximum
5:00)
Machine
Action
Pause
Initial
Drain
Fill 3.8
L+
Wash
motor
pulses
Wash+
Dispenser
(Middle
spray
pulses
arm)
Wash+
Fan
(Ceiling
spray
arm)
Wash+
Third
Level
Rack. If
present
in this
model
Wash+
Heater
(Lower
spray
arm)
Drain
Pracess
INSTALL ACCESS PANELS
Insulation
(on some models)
50.
Reinstall access panels and fasteners
Place the toe panel behind the access panel against the
dishwasher leg. If insulation is included on this model, make sure
insulation does not interfere with the float assembly. Push the
access panel up toward the top of the product so that it hangs on
the hooks on the plastic side members.
Reinstall the toe/access panel assy.With side shield to go
between the toe/access panel
assembly and the side member.
Align the rectangular slot in the foam and assembly the toe/
access panel assembly to the unit using the screw.
NOTE:
Remove film on door Score around door for easier
removal.
Check that the lower edge of the access panel touches the floor.
Adjust if necessary.
51.