Maytag MDD8000AWS Installation Instructions - Page 5
Water Supply Requirements - dimensions
UPC - 883049140759
View all Maytag MDD8000AWS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Product Dimensions 24" (61 cm) Preferred utility area 23³⁄₈" (59.5 cm) 33³⁄₄" (85.7 cm) A ¹⁄₂" (1.3 cm) 25" (63.5 cm) B 8" (20.3 cm) 19¹⁄₄" (48.9 cm) 1¹⁄₂" (3.75 cm) Installation Clearances Cutout dimensions 24" (61 cm) 24" (61 cm) 33⁷⁄₈" (85,7 cm) A. Choose left-hand or right-hand drain and water connection route. B. Choose left-hand or right-hand electric connection route. NOTE: All holes should be drilled at 1½" (3.8 cm) diameter. Water Supply Requirements ■ A hot water line with 20-120 psi (138-862 kPa) water pressure. ■ 120°F (49°C) water temperature at dishwasher. ■ Flexible braided fill line (½" minimum plastic tubing is not recommended). 5
5
Product Dimensions
Installation Clearances
Cutout dimensions
Preferred utility area
NOTE:
All holes should be drilled at 1½" (3.8 cm) diameter.
Water Supply Requirements
■
A hot water line with 20-120 psi (138-862 kPa) water pressure.
■
120°F (49°C) water temperature at dishwasher.
■
Flexible braided fill line (½" minimum plastic tubing is not
recommended).
23
³⁄₈
"
(59.5 cm)
19
¹⁄₄
"
(48.9 cm)
1
¹⁄₂
"
(3.75 cm)
24"
(61 cm)
33
³⁄₄
"
(85.7 cm)
24"
24"
(61
cm)
33
⁷⁄₈
"
(85,7 cm)
(61 cm)
A. Choose left-hand or right-hand drain and water connection route.
B. Choose left-hand or right-hand electric connection route.
A
B
25"
(63.5 cm)
¹⁄₂
"
(1.3 cm)
8"
(20.3 cm)