Frequently asked questions Cleaning the drain pump and non-return valve If the water has not been pumped away at the end of a program, the drain pump or the non-return valve might be blocked. They are, however, easy to clean. Turn off the dishwasher and pull the plug. Take the filter system out of the wash cabinet (see "Cleaning and care Cleaning the filters"). Scoop the water out of the cabinet using a suitable container or utensil. The drain pump is beneath the non-re‐ turn valve (see arrow). Remove all foreign objects from the drain pump (glass or bone splinters). Before returning the non-return valve, check that the drain pump is not blocked. Spin the propeller sever‐ al times in both directions to check for obstructions. Carefully reinsert the non-return valve and secure it with the locking clamp. Make sure the locking clamp clicks into place! Press the catch for the non-return valve inwards . Lift the non-return valve up and out and rinse well under running water. Remove all foreign objects from the non-return valve. Be careful not to damage any delicate components when cleaning the drain pump and the non-return valve. 60